MNL000448.doc
Revision 00
09/19/2016
© Versum Materials, Inc. as of the revision and date shown. All rights reserved.
Confidential and Proprietary Data
Page
-
4
9.2
No or Low Purge Gas Pressure
Possible Source of
Problem
Test
Solution
Closed purge gas supply
valve
Purge gas supply pressure
regulator set incorrectly
Check position of supply
valve.
Check setting on pressure
regulator.
Open supply valve.
Set pressure regulator to
correct delivery pressure
[80-90 psig (5.5-6.2
barg)].
Low purge gas cylinder
pressure
Check cylinder pressure.
Change cylinder.
Instrument nitrogen
supply not adequate to
open purge gas pneumatic
valves
Purge gas pressure
transducer(s)
malfunctioning
Check instrument nitrogen
pressure.
Check input to controller,
Check connections and
signal from pressure
transducers.
Adjust to 85-95 psig
(5.9-6.6 barg) if
necessary.
Repair connections,
repair or replace
transducer(s) as
necessary.