2.2.2
Source Cup Assembly
The Source Cup Assembly provides local control of the temperature and monitoring of
level and control circuits. It also provides the interface between the high powered
electronics and the heater/cooling elements. The Source Cup Assembly is equipped
with coolers, heaters and a temperature-sensing probe. The heater offsets the effect of
the cooler to attain the temperature within the specified range.
A multiple conductor cable connects the Source Cup Assembly to the Power Supply
Module providing current paths for the cooler and heater. The green checked
pushbutton located on the keypad illuminates the back light to view the liquid level
through the window on the Source Cup Assembly. The bubbler containing the chemical
is placed in the Source Cup Assembly, refer to figure 2-1. The Source Cup Assembly
allows for easy access, installation, maintenance, and replacement of the bubblers.
The front panel controls consist of a Start/Stop switch and a keypad/LCD interface.
The front panel controls are further described in Chapter 5.