MNL000424.doc
Revision 00
08/26/2016
© Versum Materials, Inc. as of the revision and date shown. All rights reserved.
Confidential and Proprietary Data
Page
-
33
Table 6‐6
Ultrasonic Level Interface
Ultrasonic Level J5* (CPC)
Pin #
Signal name
Description
1
+24
Supply power for Ultrasonic Probe
2
No connection
No connection
3
GNDD
Signal ground
4
Control
Relay control logic configuration setting
5
Empty
Relay contact input for Empty level
Chem level in container below sensor displays 5%, above
sensor displays 15% on display.
6
Low
Relay contact input for Low level
Chem level in container below sensor displays 15%, above
sensor displays 65% on display,
7
Mid
Relay contact input for Mid level
Chem level in container below sensor displays 65%, above
sensor displays 85% on display,
8
Full
Relay contact input for Full level
Chem level in container below sensor displays 85%, above
sensor displays 100% on display,
9
+24
Supply power for Ultrasonic Probe
10
Empty_C
Relay contact input common for Empty level
11
Low_C
Relay contact input common for Low level
12
Mid_C
Relay contact input common for Mid level
13
Full_C
Relay contact input common for Full level
14
No connection
No connection
15
Chassis gnd
Earth ground
*Used only in VG600 for SS applications