PIN 11 & 24: LEVEL #4 ALARM
(Relay K7)
-
This output provides an open or closed
contact if the level of chemical in the Bubbler goes below Level #4 set-point, selected in
the set up screen. The contact is closed when chemical in the Bubbler is above Level
#4 set-point and will open when chemical goes below Level #4 set-point.
PIN 12 & 25: LEVEL #3 ALARM
(Relay K8)
-
This output provides an open or closed
contact if the level of chemical in the Bubbler goes below Level #3 set-point, selected in
the set up screen. The contact is closed when chemical in the Bubbler is above Level
#3 set-point and will open when chemical goes below Level #3 set-point.
PIN 17 & 5: LEVEL #2 ALARM
(Relay K3)
-
This output provides an open or closed
contact if the level of chemical in the Bubbler goes below Level #2 set-point, selected in
the set up screen. The contact is closed when chemical in the Bubbler is above Level
#2 set-point and will open when chemical goes below Level #2 set-point.
PIN 18 & 6: LEVEL #1 ALARM
(Relay K4)
-
This output provides an open or closed
contact if the level of chemical in the Bubbler goes below Level #1 set-point, selected in
the set up screen. The contact is closed when chemical in the Bubbler is above Level
#1 set-point and will open when chemical goes below Level #1 set-point.
PIN 9 & 21: ISOLATED REMOTE TEMPERATURE HIGH 2/LOW 2 ALARM ‐
This
output provides an open or closed contact if the temperature exceeds the set point by
the specified number in the set up screen (in °C) for Temp High 2 and Temp Low 2.
The contact is closed when no alarm condition exists and will open when Temp High 1
or Temp Low 1 alarm occurs.