MM113 - D10/D16 Hot Melt Unit
Appendix B - Power Requirements
213
Appendix B - Power Requirements
System Power Requirement Calculation - D Series Units
WARNING!
Calculate all power requirements, as stated below, before hooking up power. OTHERWISE,
DEATH OR SEVERE INJURY AND DAMAGE TO EQUIPMENT AND/OR THE CIRCUIT
COULD OCCUR.
Power requirements for the D10/D16 System (unit, hoses and guns) must be calculated before hooking up power, to
verify that the hoses and guns do not exceed the power rating for the D Series unit. Personnel injury, as well as
serious equipment damage, can result from overloading the system.
This calculation will depend on the following two factors:
•
The wattage for any hose/gun pair
•
The total wattage for all hoses and guns
Perform the system power requirement calculation for the D Series unit as follows, referring to Table 1, below:
Table 1. Maximum Allowable Wattage for the D Series Unit
Line
Description
Maximum
Wattage (W)
1
Total for hose/gun 1 pair
1800
2
Total for hose/gun 2 pair
1800
3
Total for hose/gun 3 pair
1400
4
Total for hose/gun 4 pair
1400
5
Total for all hoses and guns
8400
1. Add the power requirements of hose #1 and gun #1. Compare this value to the maximum wattage given
in Line 1 of Table 1.
2. Add the power requirements of hose #2 and gun #2. Compare this value to the maximum wattage given
in Line 2 of Table 1.
3. Add the power requirements of hose #3 and gun #3. Compare this value to the maximum wattage given
in Line 3 of Table 1.
4. Add the power requirements of hose #4 and gun #4. Compare this value to the maximum wattage given
in Line 4 of Table 1.
5. Add the power requirements of all hoses and all guns. Compare this value to the maximum wattage for all
hoses and guns given in Line 5 of Table 1.
6. If any of the power requirements calculated in steps 1-5 exceed any of the maximum allowable wattages
given in Table 1, the hose length or gun configuration must be changed, to reduce all power requirements
to below maximum-allowable wattages.
If each of the power requirements calculated in steps 1-5 is below the maximum allowable wattages given
in Table 1, the system power requirement is within allowable limits.
Summary of Contents for D10
Page 1: ...D10 D16 Hot Melt Unit Manual Number MM113 Revision Date 8 2019 ...
Page 4: ......
Page 10: ...Table of Contents MM113 D10 D16 Hot Melt Unit 10 ...
Page 22: ...Section 2 Safety and Use MM113 D10 D16 Hot Melt Unit 22 ...
Page 24: ...Section 3 Basic Features MM113 D10 D16 Hot Melt Unit 24 ...
Page 38: ...Section 5 Setup MM113 D10 D16 Hot Melt Unit 38 Section 5 Setup Control Panel ...
Page 45: ...MM113 D10 D16 Hot Melt Unit Section 5 Setup 45 Set Language Continued Next Page ...
Page 46: ...Section 5 Setup MM113 D10 D16 Hot Melt Unit 46 Set Language Continued ...
Page 47: ...MM113 D10 D16 Hot Melt Unit Section 5 Setup 47 Set Temperature Units ...
Page 50: ...Section 5 Setup MM113 D10 D16 Hot Melt Unit 50 Hose Valve Temperature Continued ...
Page 57: ...MM113 D10 D16 Hot Melt Unit Section 5 Setup 57 Beacon 2 ...
Page 73: ...MM113 D10 D16 Hot Melt Unit Section 5 Setup 73 Sequential Start Valve ...
Page 84: ...Section 5 Setup MM113 D10 D16 Hot Melt Unit 84 VFD Parameters After 5 18 Before 5 18 ...
Page 98: ...Section 5 Setup MM113 D10 D16 Hot Melt Unit 98 ...
Page 106: ...Section 6 Operation MM113 D10 D16 Hot Melt Unit 106 ...
Page 117: ...MM113 D10 D16 Hot Melt Unit Section 9 Specifications 117 Dimensions D16 ...
Page 118: ...Section 9 Specifications MM113 D10 D16 Hot Melt Unit 118 ...
Page 121: ...MM113 D10 D16 Hot Melt Unit Section 10 Part Number List 121 D10 Unit Continued ...
Page 122: ...Section 10 Part Number List MM113 D10 D16 Hot Melt Unit 122 D10 Unit Continued ...
Page 125: ...MM113 D10 D16 Hot Melt Unit Section 10 Part Number List 125 D10 Base Unit 776xx884 ...
Page 126: ...Section 10 Part Number List MM113 D10 D16 Hot Melt Unit 126 D10 Base Unit 776xx884 Continued ...
Page 150: ...Section 10 Part Number List MM113 D10 D16 Hot Melt Unit 150 D16 Unit Continued ...
Page 151: ...MM113 D10 D16 Hot Melt Unit Section 10 Part Number List 151 D16 Unit Continued ...
Page 154: ...Section 10 Part Number List MM113 D10 D16 Hot Melt Unit 154 D16 Base Unit 776xx885 ...
Page 155: ...MM113 D10 D16 Hot Melt Unit Section 10 Part Number List 155 D16 Base Unit 776xx885 Continued ...
Page 206: ...Section 10 Part Number List MM113 D10 D16 Hot Melt Unit 206 ...
Page 208: ...Section 11 Warranty MM113 D10 D16 Hot Melt Unit 208 ...
Page 210: ...Section 12 Service MM113 D10 D16 Hot Melt Unit 210 ...
Page 214: ...Appendix B Power Requirements MM113 D10 D16 Hot Melt Unit 214 ...
Page 226: ...Appendix D Communication Protocols Modus MM113 D10 D16 Hot Melt Unit 226 ...
Page 269: ......