9.3
Nothing Happens After an Operation is Made
77
9
9.3
Nothing Happens After an Operation is Made
Table 9-1
Nothing Happens After an Operation is Made
Problem
Possible causes
Corrective action
Section
1
Power ON/OFF switch
in the ON position but
the turbo molecular
pump fails to operate.
Electrical power cable
not properly connected.
Properly connect the electrical
power cable.
5.2
Electrical power outside
power supply unit’s
power range.
Operate within power supply
unit’s power range.
4.1
2
START/STOP button is
pushed but turbo
molecular pump does
not accelerate.
In REMOTE mode.
(POWER lamp lights)
By maintained push, change to
LOCAL mode
(POWER lamp blinks)
6.2
Other causes.
Check the Alarm lamp is not lights
in orange. If an alarm is indicated,
correct the malfunction and reset
alarm.
9.5
3
Remote "STOP" signal
active but the turbo
molecular pump does
not accelerate.
In LOCAL mode.
(POWER lamp blinks)
By maintained push, change to
REMOTE mode.
(POWER lamp lights)
6.2
"STOP" signal active.
Deactivate "STOP" signal.
6.7
Other problems.
Check the Alarm lamp is not ON.
If an alarm is indicated, correct
the malfunction and reset.
9.5
4
START/STOP button is
pushed but the turbo
molecular pump does
not decelerate.
In REMOTE mode.
(POWER lamp lights)
By maintained push, change to
LOCAL mode.
(POWER lamp blinks)
6.2
5
Remote "STOP" signal
activated but the turbo
molecular pump does
not decelerate.
In LOCAL mode.
(POWER lamp blinks)
By maintained push, change to
REMOTE mode.
(POWER lamp lights)
6.2
Summary of Contents for UTM1600 Series
Page 2: ...This page is intentionally left blank...
Page 10: ...viii Location of Label...
Page 26: ...12 2 2 4 External I F Panel This page is intentionally left blank...
Page 32: ...18 3 3 3 Controller This page is intentionally left blank...
Page 38: ...24 4 4 4 Standards Fulfilled This page is intentionally left blank...
Page 54: ...40 5 5 5 Notes on Transportation This page is intentionally left blank...
Page 78: ...64 6 6 8 Communication Specifications This page is intentionally left blank...
Page 79: ...7 7GAS PURGE...
Page 88: ...74 8 8 6 Turbo Molecular Pump Return Request This page is intentionally left blank...
Page 101: ...10 10WARRANTY CLAUSES...
Page 104: ...90 10 This page is intentionally left blank...
Page 106: ...Index Index 2 This page is intentionally left blank...