(1) When using, as a backing vacuum pump, a vacuum pump with no check mechanism
(backstream flow prevention) such as dry vacuum pump, etc., install a forevacuum valve
between the turbo molecular pump and the backing vacuum pump to prevent rapid inverse
flow of exhausted gas. And close the forevacuum valve before the backing vacuum pump
stops. (Refer to Fig. 5-8)
(2) Even when "ALARM" signal is emitted, don't cut off the power supply while "ROTATION"
signal is being emitted. Even when ALARM lamp lights, don't cut off the power supply while
NORMAL lamp blinking.
(3) If "ALARM" signal is emitted or ALARM lamp lights, shut down the backing vacuum pump
or close the forevacuum valve immediately. Furthermore, when main valve is installed
between the turbo molecular pump and the vacuum chamber, close this valve, too.
(4) Provide a flowmeter on the downstream of cooling water line, otherwise the turbo
molecular pump will shut down and otherwise set up the interlock which the pump can not
start against cut off of water supply.
5.5
Notes on Transportation
This product is precision equipment. Do not give any strong impact or continuous vibration in
transportation, otherwise the product could be damaged. In transportation, please use a means
of transportation which have vibration-proof function (an air suspension truck, for example).
Especially when passing by rough road, we recommend that the product is transported keeping
the packing condition when it ships from ULVAC.
When the product is put on the high temperature / humidity environment for a long time, it
causes the breakdown of the product due to corrosion of mechanical parts or performance loss
of electrical parts.
Please transport or store the product under an appropriate environment.
Summary of Contents for UTM1600 Series
Page 2: ...This page is intentionally left blank...
Page 10: ...viii Location of Label...
Page 26: ...12 2 2 4 External I F Panel This page is intentionally left blank...
Page 32: ...18 3 3 3 Controller This page is intentionally left blank...
Page 38: ...24 4 4 4 Standards Fulfilled This page is intentionally left blank...
Page 54: ...40 5 5 5 Notes on Transportation This page is intentionally left blank...
Page 78: ...64 6 6 8 Communication Specifications This page is intentionally left blank...
Page 79: ...7 7GAS PURGE...
Page 88: ...74 8 8 6 Turbo Molecular Pump Return Request This page is intentionally left blank...
Page 101: ...10 10WARRANTY CLAUSES...
Page 104: ...90 10 This page is intentionally left blank...
Page 106: ...Index Index 2 This page is intentionally left blank...