RF Power Supply and Matching Box
2. Overview
19
Classification
Item
Specification value
AMC-8L/AMC-9L/AMC-8LT/AMC-9LT
Input
Input voltage
100 VAC
Fluctuation
range
±
10% (90 to 110 V)
Phase,
frequency
Single phase, 50/60 Hz
Input capacity
150 VA
Leakage current 3 mA or less
Insulation resistance
10 M
Ω
or more with a 500 VDC insulation tester (between AC LINE and
CASE)
Withstand voltage
1500 VAC/min at 50/60 Hz (between AC LINE and CASE)
Ambient temperature during
operation
0
°
C to 40
°
C
Ambient humidity during
operation
15% to 85% RH (no condensation)
Operating environment
Avoid direct sunlight, heat, dust, vibration
Not containing corrosive gas
Exterior
Exterior
dimensions
AMC-8L(T): 480 W x 350 D x 50 H (not including protrusions)
AMC-9L(T): 480 W x 300 D x 50 H (not including protrusions)
Weight
Approx. 5 kg
RF system
VPP rating
VDC rating
RFS-1305L
/ MBX-1305L-LV
50 ~ 1000 V
-50V ~ -1000 V
RFS-1310L
/ MBX-1310L-LV
RFS-1330L
/ MBX-1330L-LV
RFS-1305L
/ MBX-1305L(u)
125 ~ 2500 V
-250V ~ -2500 V
RFS-1310L
/ MBX-1310L
250 ~ 5000 V
RFS-1330L
/ MBX-1330L
RFS-1350LH
/ MBX-1350L
500V ~ 10 kV
RFS-13100L / MBX-13100L
RFS-2750L
/ MBX-2750L
750V ~ 15 kV
None
RFS-2775L
/ MBX-2775L
RFS-1330L
/ MBX-1330Lu
Table 2-15 Matching box individual specifications
Table 2-16 VPP/VDC rating