![Ubiquiti ES-24-250W Administration Manual Download Page 90](http://html2.mh-extra.com/html/ubiquiti/es-24-250w/es-24-250w_administration-manual_3227362090.webp)
89
Configuring System Information
EdgeSwitch
™
Administration Guide
Ubiquiti Networks, Inc.
Time-Based Flow Statistics Fields
Field
Description
Reporting Methods
The methods for reporting the collected statistics at the end of every configured interval:
•
None
The statistics are not reported to the console or an external server. They can be viewed only
by using the EdgeSwitch UI or by issuing a CLI command.
•
Console
The statistics are displayed on the console.
•
The statistics are sent to an e-mail address. The SNTP server and e-mail address
information is configured by using the appropriate
Email Alerts
pages.
•
Syslog
The statistics are sent to a remote syslog server. The syslog server information is
configured on the
Logging Hosts
page.
To change the reporting methods for all flow-based statistics rules, click this button and select
one or more methods.
Click this button to reset the field to the default value.
Rule Id
The number that identifies the flow-based statistics collection rule.
Time Range
The name of the periodic or absolute time range to use for data collection. The time range is configured
using the
Time Range Entry Summary
page (see
“Time Range Entry Configuration” on page 111
).
The time range must be configured on the system before the time-based statistics can be collected.
Match Conditions
The criteria that a packet must meet to match the rule.
Interfaces
The interface or interfaces on which the flow-based rule is applied. Only traffic on the specified
interfaces is checked against the rule.
When you click
Add
, the
Time Based Flow Configuration
dialog box opens and allows you to configure a rule for traffic flow statistics.
The match conditions are optional, but the rule must specify at least one match condition. The match conditions are as follows:
Match All
Select this option to indicate that all traffic matches the rule and is counted in the statistics. This
option is exclusive to all other match criteria, so if
Match All
is selected, no other match criteria can be
configured.
Source IP
The source IP address to match in the IPv4 packet header.
Destination IP
The destination IP address to match in the IPv4 packet header.
Source MAC
The source MAC address to match in the ingress frame header.
Destination MAC
The destination MAC address to match in the ingress frame header.
Source TCP Port
The TCP source port to match in the TCP header.
Destination TCP Port
The TCP destination port to match in the TCP header.
Source UDP Port
The UDP source port to match in the UDP header.
Destination UDP Port
The UDP destination port to match in the UDP header.
Use the buttons to perform the following tasks:
• To add a rule and define criteria for flow-based statistics that are collected within a time range, click
Add
.
In the
Time Based Flow Configuration
dialog box, configure the settings, and then click
Submit
to apply
the changes.
• To delete one or more flow-based rules for time-based statistics, select each entry to delete and click
Remove
.
• Click
Refresh
to refresh the data on the screen with the present state of the data in the switch.
To retain the changes across the switch’s next power cycle, click
System
>
Configuration Storage
>
Save
.