Ubiquiti Networks, Inc.
Summer Time Configuration Fields
Field
Description
Summer Time
The summer time mode on the system:
•
Disable
Summer time is not active, and the time does not shift based on the time of year.
•
Recurring
Summer time occurs at the same time every year. The start and end times and dates for
the time shift must be manually configured.
•
EU
The system clock uses the standard recurring summer time settings used in countries in the
European Union. When this field is selected, the rest of the applicable fields on the page except
Offset
and
Zone
are automatically populated and cannot be edited.
•
USA
The system clock uses the standard recurring daylight saving time settings used in the
United States. When this field is selected, the rest of the applicable fields on the page except
Offset
and
Zone
are automatically populated and cannot be edited.
•
Non-Recurring
Summer time settings are in effect only between the start date and end date
of the specified year. When this mode is selected, the summer time settings do not repeat on an
annual basis.
Date Range
– The fields in this section are available only if the
Summer Time
field is set to
Non-Recurring
mode.
Start Date
The day, month, and year that summer time begins. To change the date, click
next to the field,
select the year from the menu, browse to the desired month, and click the date.
Starting Time and Day
The time, in hours and minutes, to start summer time on the specified day.
End Date
The day, month, and year that summer time ends. To change the date, click
next to the field, select
the year from the menu, browse to the desired month, and click the date.
Ending Time of Day
The time, in hours and minutes to end summer time on the specified day.
Recurring Date
– The fields in this section are available only if the
Summer Time
field is set to
Recurring
mode.
Start Week
The week of the month within which summer time begins.
Start Day
The day of the week on which summer time begins.
Start Month
The month of the year within which summer time begins.
Starting Time of Day
The time, in hours and minutes, to start summer time.
End Week
The week of the month within which summer time ends.
End Day
The day of the week on which summer time ends.
End Month
The month of the year within which summer time ends.
Ending Time of Day
The time, in hours and minutes, to end summer time.
Zone
– The fields in this section are available for all modes selected from the
Summer Time
field except
Disable
.
Offset
The number of minutes to shift the summer time from the standard time.
Zone
The acronym associated with the time zone when summer time is in effect.
Use the buttons to perform the following tasks:
• If you make any changes to the page, click
Submit
to apply the settings.
• Click
Refresh
to refresh the page with the most current data from the switch.
To retain the changes across the switch’s next power cycle, click
System
>
Configuration Storage
>
Save
.