SmartPass® Integrated Reader 2450 MHz (High Voltage) System Guide
6171 Enable Echo Mode (Factory Default)
Command 6171 enables the reader to echo received host commands. Refer to
command 6170 for more information.
Reader message:
Done or Erro
r
620N Output Control
These commands provide direct control of two output lines that may be used to
operate external hardware such as gates or traffic lights. Receipt of any 620N
command automatically disables predefined output mode command 621. The value
for
N
specifies the output status as follows:
Table 9-13 Output Control Option Commands
Command
Output Control Option
6200
Turn both output ports off
6201
Turn output0 on, output1 off
6202
Turn output1 on, output0 off
6203
Turn both output ports on
Reader message:
Done
The host will not be able to directly control output1 if either Wiegand mode
(command 451) or the external check tag option (command 8161) is enabled.
621 Predefined Output Control (Factory Default)
Command 621 configures the reader for predefined output mode. In this mode, both
output lines, output0 and output1, are automatically asserted upon receipt of a valid
unique tag ID. The output line will remain asserted for the time specified by output
pulse duration (command 67N). Any direct control command (620N) will
automatically disable predefined output mode.
Reader message:
Done
If predefined output mode is enabled, the reader will not assert output1 upon receipt
of a tag ID if Wiegand mode is enabled (command 451) or if the external check tag
option is enabled (command 8161).
63 Reset Reader
Command 63 resets the power fail bit, clears all buffers, resets tag uniqueness, turns
both output lines off, transmits the sign-on message, and returns to the data mode.
Reader message:
Model [software version] SNYYYYYY
[Copyright notice]
9-40
Summary of Contents for SmartPass AI1611
Page 4: ......
Page 17: ...A Glossary...
Page 18: ......
Page 22: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide A 6...
Page 23: ...B System Specifications...
Page 24: ......
Page 26: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide B 4...
Page 27: ...C Wiring Tables...
Page 28: ......
Page 32: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide C 6...
Page 33: ...1 Introduction...
Page 34: ......
Page 40: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 1 8...
Page 41: ...2 Preparing the Site...
Page 42: ......
Page 52: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 2 12...
Page 53: ...3 Quick SmartPass Test...
Page 54: ......
Page 63: ...4 Installing Tags on Vehicles...
Page 64: ......
Page 71: ...5 Installing SmartPass...
Page 72: ......
Page 90: ...6 General Software Information...
Page 91: ......
Page 99: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 6 10...
Page 100: ...7 Modes of Operation...
Page 101: ......
Page 106: ...8 Communication Protocols...
Page 107: ......
Page 124: ...9 Commands...
Page 125: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 9 2...
Page 174: ...10 Troubleshooting...
Page 175: ......
Page 179: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 10 6...