Commands
TF
infinite, never expires (factory default)
I0
input inversion disabled (factory default)
I1
input inversion enabled
For example, if factory default settings are assigned, the reader message is:
PRST P0 D0 A2 TF I0
Presence without tag reports disabled, minimum presence true period is 0, RF-off
control on timeout or presence false, infinite RF timeout, and input inversion
disabled
530 Display RF0 Filter Status
Command 530 displays the parameter set for the RF channel input, including the
selected unique ID code criteria (command 410N) and the valid ID code criteria,
which are fixed at one acquisition.
Reader message:
RF0S U<0-3> V0
where
U0
one ID separation (factory default)
U1
two ID separation
U2
transmit all IDs
U3
buffer all IDs
V0
valid ID code criteria of one acquisition (fixed)
For example, if factory default settings are assigned, the reader message is:
RF0S U0 V0
Separation of one ID for uniqueness filtering and a valid ID code criteria of one
acquisition
532 Display Wiegand Mode Status
Command 532 displays Wiegand mode status enabled or disabled.
Reader message:
TOF <0-1>
where
0
Wiegand mode disabled
1
Wiegand mode enabled
533 Display Wiegand Retransmit Interval
Command 533 displays the Wiegand retransmit interval. This interval specifies the
delay (in seconds) before the reader will retransmit Wiegand data for a tag still in the
read zone. The factory default is 1 second.
9-33
Summary of Contents for SmartPass AI1611
Page 4: ......
Page 17: ...A Glossary...
Page 18: ......
Page 22: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide A 6...
Page 23: ...B System Specifications...
Page 24: ......
Page 26: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide B 4...
Page 27: ...C Wiring Tables...
Page 28: ......
Page 32: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide C 6...
Page 33: ...1 Introduction...
Page 34: ......
Page 40: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 1 8...
Page 41: ...2 Preparing the Site...
Page 42: ......
Page 52: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 2 12...
Page 53: ...3 Quick SmartPass Test...
Page 54: ......
Page 63: ...4 Installing Tags on Vehicles...
Page 64: ......
Page 71: ...5 Installing SmartPass...
Page 72: ......
Page 90: ...6 General Software Information...
Page 91: ......
Page 99: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 6 10...
Page 100: ...7 Modes of Operation...
Page 101: ......
Page 106: ...8 Communication Protocols...
Page 107: ......
Page 124: ...9 Commands...
Page 125: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 9 2...
Page 174: ...10 Troubleshooting...
Page 175: ......
Page 179: ...SmartPass Integrated Reader 2450 MHz High Voltage System Guide 10 6...