3-162
3.12 Memory card
Use the memory card for saving the data measured by
this instrument supplied. The operation of this instru-
ment will not be guaranteed, if a memory card other than
supplied with this instrument is used.
Neither of change nor deletion of the data saved in the
memory card by personal computer is allowed, since
such data will not otherwise be displayed by this instru-
ment.
3.12.1
How to read the information saved in the memory card by the personal computer
incorporating the contents of the memory card saved in the memory card.
The data saved in the memory card of this instrument can be confirmed
by the Windows personal computer providing the PC card slot.
1) Insert the memory card into the PC card slot of the personal
computer.
If inserting the memory card into the personal computer for
the first time, see the instruction manual for said personal
computer.
2) Open the Explorer and make access to the removable disk
where the memory card has been inserted.
3) The following directories are displayed by the type saved
in this instrument.
3.12 Memory card
Format
Directory name
File to be saved
File name
File Size (*3)
Echo (*4)
Jpeg (*4)
Axial length
(*5)
BDIAG_E
Patient data and image data of the B-scan
image diagnosis function (*1)
ID number .b??
(*2)
Approx. 66K
Byte
BAXL_E
Patient data and image data of the axial
length measurement sub-function (*1)
ID number .x??
(*2)
Approx. 66K
Byte
ADIAG
Patient data and waveform data of the A-
scan diagnosis function (*1)
ID number .d??
(*2)
Approx. 0.8K
Byte
JPEG image file of the B-scan diagnosis
function
Input file name
.jpg
Approx. 35 to
70K Byte
BDIAG_J
Text file of patient data
Input file name
.txt
Approx. 0.3K
Byte
JPEG image file of axial length measureing
sub-function
Input file name
.jpg
Approx. 35 to
70K Byte
BAXL_J
Text file of patient data
Input file name
.txt
Approx. 0.4K
Byte
AXIALDT
Patient data and waveform data of the axial
length measuring function (*1)
ID number. a ??
(*2)
Approx. 1.8K
Byte
*1: The data can be loaded on UD and cannot be loaded on PC. Patient data is saved as Text style, while Image and
waveform as Binary
*2: Numbers are automatically typed in, on ?? part in the table
*3: File Size may vary, depending on settings. Since shrinking rate changes as different image date type, above sizes are
only for reference.
*4: A folder as its name of Patient ID, is created under each folder for Echo and JPEG images. Each file per patient is
saved under the folder. 2048 patients can be saved on each folder. 1296 data can be saved on each patient folder.
*5: 2048 Data can be saved on AXIALDT folder.
Summary of Contents for UD-600
Page 2: ......
Page 14: ...xii This page is intentionally blank...
Page 22: ...1 8 This page is intentionally blank...
Page 28: ...2 6 This page is intentionally blank...
Page 157: ...3 129 Simple mode 3 9 Printout...
Page 159: ...3 131 Simple mode 3 9 Printout...
Page 192: ...3 164 This page is intentionally blank...
Page 256: ...8 14 This page is intentionally blank...
Page 260: ...A 4 INDEX...
Page 262: ...0123 ID 0608...