Contact Microphone Settings
Perform settings for using the ‘Contact Microphone.’ For the IP-300RM, use the
following screen:
Item
Description
Cancel All Broadcasting
Destination SW settings
SW Contact
Set the switch that cancels all broadcasting
destination settings
Chime SW settings
SW Contact
Set the switch that designates whether or not to sound
a chime tone
SW-LED Contact
Set the chime enable or disable indications, and also
the chime status indications.
Microphone SW settings
SW Contact
Set the switch for staring microphone broadcasts.
Contact classification
Select either ‘Lock’ or ‘Non-lock.’*
Contact for Broadcast In-
progress LED
Set the microphone broadcast status indications
External input SW settings
Playing Equipment
Select the playing equipment (from among those
set on the ‘Playing Equipment Settings’ screen).
Musical Numbers
Enter the musical numbers (enter the musical number
range set on the ‘Playing Equipment Settings’ screen).
SW Contact]
Set the switch to start broadcasts.
Contact for External Input
In-Progress LED[
Set the broadcast status indications
Emergency microphone
SW settings
SW Contact
Set the switch to start emergency broadcasts.
Contact Classification]
Select either ‘Lock’ or ‘Non-lock.’*
Contact for ‘Emergency
Broadcast In-Progress’
LED
Set the emergency broadcast status indications.
Recording function
Select either ‘Enable’ or ‘Disable.’
Recording In-Progress
LED settings
SW-LED Contact
Set the recording in-progress status indications
Playback SW settings
SW Contact
Set the switch that plays back the recording contents.
SW-LED Contact
Set the recording content playback status indications.
Monitor settings
SW Contact
Set the switch that selects the monitor audio input.
Audio Input
Select the audio input channel (from among the
channels for which the audio input classification has
been set to ‘Monitor’ on the ‘Equipment Settings’
screen).
SW-LED Contact
Set the ‘Monitor Selection in Progress’ status
indications.
Signal/Peak settings
Signal-LED Contact
Set the status indications for when the microphone
input level exceeds Signal level (−40 dB).
Peak-LED Contact
Set the status indications for when the microphone
input level exceeds Peak level (+8 dB).