III-3
Instrument Operation
Thermo Scientific Orion 2111LL Sodium Monitor User Guide
ROSS and the COIL tradedress are trademarks of Thermo Fisher Scientific Inc. US Patent 6,793,787
Default
User Action
Marquee
Scrolling
Main Display
top line
bottom line
Notes
TEST
TEST
(flashing)
SEL
SCrn
Press
to test mAmp outputs (4-
20), relays (rLY), and the air pump (AIr)
DIAGNOSTICS
appears above
SETUP in mode
window
To Select: tOUt
4-0
Press
/
to scroll through
4-20, rLY, and AIr setting. Select 4-20
SELECT mA OR RELAY
tESt
4-20
(Flashing)
Press
to test 4-20 outputs
SELECT TEMP OR SENSOR OUTPUT tOUt or SOUt
(Flashing)
Press
/
to toggle
between SOUt and tOUt. Select tOUt
SELECT TEMP OR SENSOR OUTPUT tOUt
(Flashing)
Press
for tOUt; low value (LO)
Actual
LO Value
Displayed
mA TEMP OUTPUT LOW VALUE
LO
#. # C
4 .0 mA are sourced
at output terminal
Press
for tOUt; high value (HI)
Actual
HI Value
Displayed
mA TEMP OUTPUT HIGH VALUE
HI
#. # C
0 mA are sourced
at output terminal
Press
to return user to main
setup menu for TEST submenu
TEST
(Flashing)
SEL
SCrn
Press
to test mAmp outputs
(4-20), relays (rLY), and the air pump
(AIr)