Operating Instructions Standard HMI
7-6
Then the unit running time hourmeters are shown for 30 seconds. The diesel engine run time hours and Diesel Icon are shown in
the upper display. If the optional Electric Standby Feature is installed, the electric motor run time hours and Electric Icon are
shown in the lower display.
A Full Pretrip Test is initiated from this display by pressing and holding the Pretrip Key as shown later in this section.
Electric Motor Run Time Hours
and Electric Icon
When the unit is ready to run the Standard Display of box temperature and setpoint appears. The box temperature and Box Temp
Icon are shown in the upper display. The setpoint and Setpoint Icon are shown in the lower display. The box temperature shown
in Figure is 2.1 C (35.8 F) with a 1.6 C (35 F) setpoint.
Standard Display of Box temperature and Setpoint
Pressing the OFF Key stops unit operation. The unit shuts down immediately and the display goes blank. To start the unit again,
press the ON Key.
Off Key
The Standard Display
The Standard Display is the default display that appears if no other display function is selected. The Standard Display shows the
box temperature and setpoint. The box temperature is that measured by the return air sensor. The box temperature and Box
Temperature Icon are shown in the upper display. The setpoint and Setpoint Icon are shown in the lower display. The box
temperature in Figure is 2.1 C with a 1.7 C setpoint.
Standard Display
Changing the Setpoint
From the Standard Display, press the UP ARROW Key and/or DOWN ARROW Key until the desired setpoint is shown.
1. On Key
2. Red Alarm LED
3. Setpoint
4. Box Temperature
5. UP Arrow
6. Off Key
7. Cycle Sentry/Continuous
Run
8. High Speed Lockout
9. Defrost
10. Pre-trip Test
11. Enter
12. Down Arrow
1
2
3
4
5
6
7
8
9
10
11
12
Summary of Contents for T-1000R
Page 14: ...Safety Precautions 2 6 Warning Decals 2e24151g0 ...
Page 34: ...Maintenance Inspection Schedule 4 10 ...
Page 57: ...Unit Description 5 23 Purge Mode UT Series 1 3 4 5 2 ...
Page 67: ...Unit Description 5 33 Zone 1 Cool and Zone 2 Cool UT SPECTRUM Units ...
Page 69: ...Unit Description 5 35 Purge Mode UT SPECTRUM Units ...
Page 71: ...Unit Description 5 37 Zone 1 Cool and Zone 2 Heat UT SPECTRUM Units ...
Page 72: ...Unit Description 5 38 ...
Page 74: ...Diesel Electric Menu 6 28 Adjust Brightness 6 29 Time 6 30 ...
Page 120: ...Operating Instructions Standard HMI 7 18 ...
Page 152: ...Engine Maintenance 9 14 T Series Fuel and Oil System Components TK 376 ...
Page 154: ...Engine Maintenance 9 16 T Series Fuel and Oil System Components TK 270 ...
Page 156: ...Engine Maintenance 9 18 UT Series Fuel System Components AMA768 ...
Page 172: ...Engine Maintenance 9 34 T Series Engine Mounting Components for 2 Cylinder Engine ...
Page 184: ...Engine Maintenance 9 46 ...
Page 238: ...Refrigeration Maintenance 10 54 ...
Page 246: ...Clutch Maintenance 11 8 ...
Page 258: ...Structural Maintenance 12 12 ...
Page 264: ...Mechanical Diagnosis 13 6 ...
Page 265: ...14 Electric Standby Diagnosis ...
Page 268: ...Electric Standby Diagnosis 14 4 ...
Page 269: ...15 Refrigeration System Diagnosis ...
Page 272: ...Refrigeration System Diagnosis 15 4 ...
Page 280: ...Remote Evaporators 16 8 ...