Operating Instructions Standard HMI
7-5
In Figure 1, Zone 1 is being shown on the display. The box temperature in Zone 1 is -22.3°C and the setpoint is -23°C.
ZONE 1
In the screen in Figure 2, Zone 2 is being shown on the display. The box temperature in Zone 2 is 2.1°C and the setpoint is
1.7°C.
ZONE 2
In Figure 3, Zone 3 is being shown on the display. The box temperature in Zone 3 is 9.3°C and the setpoint is 10°C. Zone 3 only
appears on units configured with 3 zones.
ZONE 3
Turning the Unit On and Off
(UT-Series only): Verify the Base Controller On/Off Switch is turned on before turning on the HMI Control Panel. The Base
Controller On/Off switch is located on the outside of the control box side on of the unit. If the Standard Truck HMI Control
Panel is turned on and the Base Controller On/Off Switch is turned off, the HMI display screen will flash on and off.
The unit is turned on by pressing the ON Key and off by pressing the OFF Key. When the ON Key is pressed the display briefly
shows dashes as the display initializes.
Keys and LED Indicators
When two horizontal bars are present at the left side of the box temperature, then Zone 2
is being shown on the display. The display will automatically scroll through all
configured zones, showing each zone for 10 seconds.
When three horizontal bar is present at the left side of the box temperature, then Zone 1 is
being shown on the display. The display will automatically scroll through all configured
zones, showing each zone for 10 seconds.
IMPORTANT: If the unit is configured as a 2 zone unit, Zone 3 will still appear in
Automatic Zone Scrolling and Manual Zone Selection mode. However, Zone 3 is turned
off and cannot be turned on.
Summary of Contents for T-1000R
Page 14: ...Safety Precautions 2 6 Warning Decals 2e24151g0 ...
Page 34: ...Maintenance Inspection Schedule 4 10 ...
Page 57: ...Unit Description 5 23 Purge Mode UT Series 1 3 4 5 2 ...
Page 67: ...Unit Description 5 33 Zone 1 Cool and Zone 2 Cool UT SPECTRUM Units ...
Page 69: ...Unit Description 5 35 Purge Mode UT SPECTRUM Units ...
Page 71: ...Unit Description 5 37 Zone 1 Cool and Zone 2 Heat UT SPECTRUM Units ...
Page 72: ...Unit Description 5 38 ...
Page 74: ...Diesel Electric Menu 6 28 Adjust Brightness 6 29 Time 6 30 ...
Page 120: ...Operating Instructions Standard HMI 7 18 ...
Page 152: ...Engine Maintenance 9 14 T Series Fuel and Oil System Components TK 376 ...
Page 154: ...Engine Maintenance 9 16 T Series Fuel and Oil System Components TK 270 ...
Page 156: ...Engine Maintenance 9 18 UT Series Fuel System Components AMA768 ...
Page 172: ...Engine Maintenance 9 34 T Series Engine Mounting Components for 2 Cylinder Engine ...
Page 184: ...Engine Maintenance 9 46 ...
Page 238: ...Refrigeration Maintenance 10 54 ...
Page 246: ...Clutch Maintenance 11 8 ...
Page 258: ...Structural Maintenance 12 12 ...
Page 264: ...Mechanical Diagnosis 13 6 ...
Page 265: ...14 Electric Standby Diagnosis ...
Page 268: ...Electric Standby Diagnosis 14 4 ...
Page 269: ...15 Refrigeration System Diagnosis ...
Page 272: ...Refrigeration System Diagnosis 15 4 ...
Page 280: ...Remote Evaporators 16 8 ...