Remote Evaporators
16-7
ELECTRICAL MAINTENANCE
SR-2/3 Multi-Temp Microprocessor Controlled Components
Refer to the Truck SR-2/3 Multi-Temp Diagnostic Manual TK 54293 for information about maintenance of the microprocessor
controlled components.
Unit Wiring
Inspect the unit wiring and wire harnesses during scheduled maintenance inspections for loose, chaffed or broken wires to protect
against unit malfunction due to opens or shorts.
STRUCTURAL MAINTENANCE
Unit Inspection
Inspect the unit during the unit pretrip inspection and scheduled maintenance inspections for loose or broken wires or hardware,
compressor oil leaks, or other physical damage which might affect unit performance and require repair or replacement of parts.
Defrost Drains
Clean the defrost drains during scheduled maintenance inspections to make sure the lines remain open.
Evaporator Coil
Clean the evaporator coil during scheduled maintenance inspections by blowing compressed air from the top side of the coil down
toward the bottom (the direction opposite the normal air flow). Inspect the coil and fins for damage, and repair if necessary.
REMOTE EVAPORATOR SYSTEM DIAGNOSIS
CAUTION: Air pressure should not be high enough to damage the coil fins.
Condition
Possible Cause
Remedy
Load temperature too high
Refrigerant shortage
Repair leak and recharge
Setpoint too high
Adjust setpoint
Expansion valve plugged
Clean or replace
Partial obstruction in low side of
refrigeration system
Locate obstruction and repair
Iced or dirty evaporator coil
Defrost or clean evaporator coil
Expansion valve open too much
Replace or adjust valve
Poor fitting trailer door
Repair or replace doors
Liquid line solenoid partially closed
or defective
Repair or replace
Evaporator fan not operating
Check and correct evaporator fan
Evaporator fan motor does not
run
Open in 2A circuit
Locate open and repair
Open in FM circuit
Locate open and repair
Open circuit between interface board
and expansion module
Locate open and repair
Defective fan motor
Replace fan motor
Defective expansion module
Replace expansion module
Summary of Contents for T-1000R
Page 14: ...Safety Precautions 2 6 Warning Decals 2e24151g0 ...
Page 34: ...Maintenance Inspection Schedule 4 10 ...
Page 57: ...Unit Description 5 23 Purge Mode UT Series 1 3 4 5 2 ...
Page 67: ...Unit Description 5 33 Zone 1 Cool and Zone 2 Cool UT SPECTRUM Units ...
Page 69: ...Unit Description 5 35 Purge Mode UT SPECTRUM Units ...
Page 71: ...Unit Description 5 37 Zone 1 Cool and Zone 2 Heat UT SPECTRUM Units ...
Page 72: ...Unit Description 5 38 ...
Page 74: ...Diesel Electric Menu 6 28 Adjust Brightness 6 29 Time 6 30 ...
Page 120: ...Operating Instructions Standard HMI 7 18 ...
Page 152: ...Engine Maintenance 9 14 T Series Fuel and Oil System Components TK 376 ...
Page 154: ...Engine Maintenance 9 16 T Series Fuel and Oil System Components TK 270 ...
Page 156: ...Engine Maintenance 9 18 UT Series Fuel System Components AMA768 ...
Page 172: ...Engine Maintenance 9 34 T Series Engine Mounting Components for 2 Cylinder Engine ...
Page 184: ...Engine Maintenance 9 46 ...
Page 238: ...Refrigeration Maintenance 10 54 ...
Page 246: ...Clutch Maintenance 11 8 ...
Page 258: ...Structural Maintenance 12 12 ...
Page 264: ...Mechanical Diagnosis 13 6 ...
Page 265: ...14 Electric Standby Diagnosis ...
Page 268: ...Electric Standby Diagnosis 14 4 ...
Page 269: ...15 Refrigeration System Diagnosis ...
Page 272: ...Refrigeration System Diagnosis 15 4 ...
Page 280: ...Remote Evaporators 16 8 ...