Operating Instructions Premium HMI
6-5
Pressing the left soft key allows the user to change the SETPOINT, and pressing the right soft key accesses the MAIN MENU.
The other two soft keys access the GAUGES menu and the SENSORS menu.
The Two Zone Premium Display
2 Zone Premium Display
The 2 Zone Premium Display in a figure shows the return air temperature and setpoint for two zones.
• The Cycle Sentry Icon in the upper right of the display shows that the unit is operating in Cycle Sentry mode.
• The return air temperature for Zone 1 is -21.3°C with a -20°C setpoint. The down-pointing arrow indicates that Zone 1 is
cooling.
• The return air temperature for Zone 2 is 2.3°C with a 2°C setpoint. The down-pointing arrow indicates that Zone 2 is also
cooling.
• The soft key under each zone is used to turn that zone on and off and allows the Setpoint for that zone to be changed.
• The soft key labeled MENU allows the Main Menu to be selected
The Three Zone Premium Display
The 3 Zone Premium Display adds the third zone for units equipped with three zones. The 3 Zone Premium Display functions
the same way as the 2 Zone Premium Display.
Operating The Unit in Single Zone Control Mode (SPECTRUM)
The following differences exist when operating the unit in Single Zone Control Mode.
• Single Zone Control Mode will appear in the Main Menu/Mode Menu only if the Single Zone Control feature has been
enabled in the Guarded Access/Main Menu Configuration menu.
• If Single Zone Control operation is selected then all zones will be forced on and will control to the same setpoint.
• Unit control is based on the temperature sensors of one zone, usually Zone 1.
• All bulkheads should be taken down to create one large compartment.
• With the exception of defrost the operating mode of each zone evaporator(s) will be same when in this mode. Unit control is
based on the temperature sensors of one zone, usually Zone 1.
• f Single Zone Control operation is selected the Single Zone Premium Display provides one soft key labeled Set Point as
shown above. This allows the setpoint for all zones to be changed simultaneously.
• If Single Zone Control operation is selected the individual zones cannot be turned off. The unit and all zones are turned On
and Off simultaneously using the On and Off hard keys at the left side of the display.
Operating The Unit at a Single Temperature (SPECTRUM)
If Single Zone Control Mode is not enabled, the unit can still be run at a single temperature.
Single Temperature
• All bulkheads should be taken down to create one large compartment.
• Turn all zones on.
• Set all zones to the same setpoint.
Summary of Contents for T-1000R
Page 14: ...Safety Precautions 2 6 Warning Decals 2e24151g0 ...
Page 34: ...Maintenance Inspection Schedule 4 10 ...
Page 57: ...Unit Description 5 23 Purge Mode UT Series 1 3 4 5 2 ...
Page 67: ...Unit Description 5 33 Zone 1 Cool and Zone 2 Cool UT SPECTRUM Units ...
Page 69: ...Unit Description 5 35 Purge Mode UT SPECTRUM Units ...
Page 71: ...Unit Description 5 37 Zone 1 Cool and Zone 2 Heat UT SPECTRUM Units ...
Page 72: ...Unit Description 5 38 ...
Page 74: ...Diesel Electric Menu 6 28 Adjust Brightness 6 29 Time 6 30 ...
Page 120: ...Operating Instructions Standard HMI 7 18 ...
Page 152: ...Engine Maintenance 9 14 T Series Fuel and Oil System Components TK 376 ...
Page 154: ...Engine Maintenance 9 16 T Series Fuel and Oil System Components TK 270 ...
Page 156: ...Engine Maintenance 9 18 UT Series Fuel System Components AMA768 ...
Page 172: ...Engine Maintenance 9 34 T Series Engine Mounting Components for 2 Cylinder Engine ...
Page 184: ...Engine Maintenance 9 46 ...
Page 238: ...Refrigeration Maintenance 10 54 ...
Page 246: ...Clutch Maintenance 11 8 ...
Page 258: ...Structural Maintenance 12 12 ...
Page 264: ...Mechanical Diagnosis 13 6 ...
Page 265: ...14 Electric Standby Diagnosis ...
Page 268: ...Electric Standby Diagnosis 14 4 ...
Page 269: ...15 Refrigeration System Diagnosis ...
Page 272: ...Refrigeration System Diagnosis 15 4 ...
Page 280: ...Remote Evaporators 16 8 ...