Operating Instructions Standard HMI
7-10
Starting the Diesel Engine
Verify the Base Controller On/Off switch is in the ON position. Diesel engine preheats and starts are automatic in both
Continuous Mode and CYCLE-SENTRY Mode. The engine will preheat and start as required when the unit is turned on. The
engine pre-heat and start sequence will be delayed in Cycle Sentry mode if there is no current need for the engine to run.
Note: If the unit is equipped with optional Electric Standby there may be some additional prompts before the engine will start.
See STARTING THE ELECTRIC MOTOR on the following pages for details.
Caution: The engine may start automatically any time the unit is turned on.
Warning: Never use starting fluid.
When the engine is preparing to start, the TSD/TSR-2/TSR-3 Standard Truck HMI Control Panel will continue to display the
Standard Display. The preheat buzzer at the unit (located on the unit Interface Board) sounds during the engine pre-heat and
crank sequence.
Starting the Electric Motor
Units equipped with the Electric Standby option only
Electric motor starting is automatic in both Continuous Mode and CYCLE-SENTRY Mode. The motor will start as required
when the unit is turned on in Standby Mode and standby power is connected.
Caution: The motor may start automatically any time the unit is turned on.
When the motor is preparing to start, the TSD/TSR-2/TSR-3 Standard Truck HMI Control Panel will continue to show the
Standard Display. The preheat buzzer at the unit (located on the unit Interface Board) sounds for 20 seconds before the electric
motor starts.Switching from Diesel to Electric
Important: The operation of this feature can be changed using the Guarded Access Menu.
Units equipped with the ELECTRIC-STANDBY option only.
The unit will automatically switch to Electric Mode operation when standby power is connected and available.
Switching from Electric to Diesel
Important: The operation of this feature can be changed using the Guarded Access Menu.
Units equipped with the ELECTRIC-STANDBY option only.
If the unit is operating in Electric Mode and the electric standby power is removed or fails, the unit will not automatically start
in Diesel mode. This is primarily designed to prevent unauthorized diesel engine starts when the truck is on a seagoing ferry
where engine operation is strictly prohibited.
If the unit is operating in Electric Mode and the electric standby power is removed or fails, Alarm Code 91 Check Electric
Ready Input will be set. The red LED between the ON key and OFF Key will glow, the Alarm Icon will glow and the box
temperature and setpoint displays will disappear as shown below.
Alarm Icon
For Alarm Code 91 Check Electric Ready Input only, pressing the OFF Key will clear the alarm and turn the unit off. Pressing
the ON key will turn the unit back on in Diesel Mode. If unit operation is required, the diesel engine will start as shown
previously in Starting the Diesel Engine.
Summary of Contents for T-1000R
Page 14: ...Safety Precautions 2 6 Warning Decals 2e24151g0 ...
Page 34: ...Maintenance Inspection Schedule 4 10 ...
Page 57: ...Unit Description 5 23 Purge Mode UT Series 1 3 4 5 2 ...
Page 67: ...Unit Description 5 33 Zone 1 Cool and Zone 2 Cool UT SPECTRUM Units ...
Page 69: ...Unit Description 5 35 Purge Mode UT SPECTRUM Units ...
Page 71: ...Unit Description 5 37 Zone 1 Cool and Zone 2 Heat UT SPECTRUM Units ...
Page 72: ...Unit Description 5 38 ...
Page 74: ...Diesel Electric Menu 6 28 Adjust Brightness 6 29 Time 6 30 ...
Page 120: ...Operating Instructions Standard HMI 7 18 ...
Page 152: ...Engine Maintenance 9 14 T Series Fuel and Oil System Components TK 376 ...
Page 154: ...Engine Maintenance 9 16 T Series Fuel and Oil System Components TK 270 ...
Page 156: ...Engine Maintenance 9 18 UT Series Fuel System Components AMA768 ...
Page 172: ...Engine Maintenance 9 34 T Series Engine Mounting Components for 2 Cylinder Engine ...
Page 184: ...Engine Maintenance 9 46 ...
Page 238: ...Refrigeration Maintenance 10 54 ...
Page 246: ...Clutch Maintenance 11 8 ...
Page 258: ...Structural Maintenance 12 12 ...
Page 264: ...Mechanical Diagnosis 13 6 ...
Page 265: ...14 Electric Standby Diagnosis ...
Page 268: ...Electric Standby Diagnosis 14 4 ...
Page 269: ...15 Refrigeration System Diagnosis ...
Page 272: ...Refrigeration System Diagnosis 15 4 ...
Page 280: ...Remote Evaporators 16 8 ...