Multichannel Selection Operation
11-70
Table 11–19. Multichannel Control Register Field Descriptions (Continued)
Name
Section
Function
RCBLK
Receive current subframe
RCBLK = 000b: Subframe 0. Element 0 to element 15
RCBLK = 001b: Subframe 1. Element 16 to element 31
RCBLK = 010b: Subframe 2. Element 32 to element 47
RCBLK = 011b: Subframe 3. Element 48 to element 63
RCBLK = 100b: Subframe 4. Element 64 to element 79
RCBLK = 101b: Subframe 5. Element 80 to element 95
RCBLK = 110b: Subframe 6. Element 96 to element 111
RCBLK = 111b: Subframe 7. Element 112 to element 127
11.6.3.2
XCBLK
Transmit current subframe
XCBLK = 000b: Subframe 0. Element 0 to element 15
XCBLK = 001b: Subframe 1. Element 16 to element 31
XCBLK = 010b: Subframe 2. Element 32 to element 47
XCBLK = 011b: Subframe 3. Element 48 to element 63
XCBLK = 100b: Subframe 4. Element 64 to element 79
XCBLK = 101b: Subframe 5. Element 80 to element 95
XCBLK = 110b: Subframe 6. Element 96 to element 111
XCBLK = 111b: Subframe 7. Element 112 to element 127
11.6.3.2
RPBBLK
Receive partition B subframe
RPBBLK = 00b: Subframe 1. Element 16 to element 31
RPBBLK = 01b: Subframe 3. Element 48 to element 63
RPBBLK = 10b: Subframe 5. Element 80 to element 95
RPBBLK = 11b: Subframe 7. Element 112 to element 127
11.6.3
XPBBLK
Transmit partition B subframe
XPBBLK = 00b: Subframe 1. Element 16 to element 31
XPBBLK = 01b: Subframe 3. Element 48 to element 63
XPBBLK = 10b: Subframe 5. Element 80 to element 95
XPBBLK = 11b: Subframe 7. Element 112 to element 127
11.6.3