Insulation resistance
Between input and chassis: 500 Vdc,
100M
Ω
or more
Between input and output: 500 Vdc, 100M
Ω
or more
Between output and chassis: 500 Vdc,
100M
Ω
or more for 30V, 80V and 250V
models.
1000Vdc, 100M
Ω
or more for 800V models.
*1: At 85 ~ 132Vac or 170 ~ 265Vac, constant load.
*2: From No-load to Full-load, constant input voltage. Measured at the sensing
point in Remote Sense.
*3: Measure with JEITA RC-9131B (1:1) probe
*4: Measurement frequency bandwidth is 10Hz to 20MHz.
*5: Measurement frequency bandwidth is 5Hz to 1MHz.
*6: From 10% to 90% of rated output voltage, with rated resistive load.
*7: From 90% to 10% of rated output voltage, with rated resistive load.
*8: Time for output voltage to recover within 0.1% + 10mV of its rated output
for a load change from 50 to 100% of its rated output current.
*9: For load voltage change, equal to the unit voltage rating, constant input
voltage.