Slew Rate
Theory
The 2260B has selectable slew rates for CC and
CV mode. This gives the 2260B power supply
the ability to limit the current/voltage draw of
the power supply. Slew rate settings are
divided into High Speed Priority and Slew
Rate Priority. High Speed Priority mode
disables slew rate settings for CC or CV mode.
Slew Rate Priority mode allows for user
adjustable slew rates for CC or CV mode. The
rising and falling slew rate can be set
independently.
Slew rate=
Disabled
Slew rate =
Enabled
Bleeder Control
Background
The 2260B DC power supplies employ a bleed
resistor in parallel with the output terminals.
2260B
Load
Bleed
resistor
Bleed resistors are designed to dissipate the
power from the power supply filter capacitors