2260B Series User Manual
106
Factory Set Value
F-88
0 = Disable
1 = Return to factory settings
Show Version
F-89
0, 1 = 2260B version
2, 3 = 2260B build year
4, 5 = 2260B build month/day
6, 7 = Keyboard CPLD version
8, 9 = Analog-Control CPLD version
A, B = Reserved
C, D = Kernel build year
E, F = Kernel build month/day
Power On Configuration Settings*
CV Control
F-90
0 = Panel control (local)
1 = External voltage control
2 = External resistance control (Ext-
R 10k
Ω
= Vo, max)
3 = External resistance control (Ext-
R
10k
Ω
= 0)
CC Control
F-91
0 = Panel control (local)
1 = External voltage control
2 = External resistance control (Ext-
R 10k
Ω
= Io,max)
3 = External resistance control
(Ext-R
10k
Ω
= 0)
Power-ON Output
F-92
0 = OFF at startup
1 = ON at startup
T001 ~ T010 = Run Test Sequence
TXX at start up
Master/Slave
F-93
0 = Master/Local
1 = Master/Parallel1
2 = Master/Parallel2
3 = Slave/Parallel
4 = Slave/Series (Only 30V, 80V
models)
External Out Logic
F-94
0 = High ON, 1 = Low ON
Power Switch trip
F-95
0 = Enable , 1 = Disable
Calibration Settings*
Calibration
F-00
0000 ~ 9999
Summary of Contents for Keithley 2260B Series
Page 14: ...2260B Series User Manual 10 Considerations 33 Grounding 36 ...
Page 43: ...OPERATION 39 Remove Test Sequence 99 Test Sequence Error Messages 100 ...
Page 52: ...2260B Series User Manual 48 Removal Reverse the procedure to remove the terminal covers ...
Page 111: ...CONFIGURATION 107 Note Power On and Calibration settings can only be set during power up ...