2260B Series User Manual
174
Rising current slew rate F-06
72.00A/s (2260B-30-36)
144.0A/s (2260B-30-72)
216.0A/s (2260B-30-108)
27.00A/s (2260B-80-13)
54.00A/s (2260B-80-27)
81.00A/s (2260B-80-40)
9.000A/s (2260B-250-4)
18.00A/s (2260B-250-9)
27.00A/s (2260B-250-13)
2.880A/s (2260B-800-1)
5.760A/s (2260B-800-2)
8.640A/s (2260B-800-4)
Falling current slew rate F-07
72.00A/s (2260B-30-36)
144.0A/s (2260B-30-72)
216.0A/s (2260B-30-108)
27.00A/s (2260B-80-13)
54.00A/s (2260B-80-27)
81.00A/s (2260B-80-40)
9.000A/s (2260B-250-4)
18.00A/s (2260B-250-9)
27.00A/s (2260B-250-13)
2.880A/s (2260B-800-1)
5.760A/s (2260B-800-2)
8.640A/s (2260B-800-4)
Internal resistance
setting
F-08
0.000
Ω
Bleeder circuit control
F-09
1 = ON
Buzzer ON/OFF control F-10
1 = ON
Measurement Average
Setting
F-17
0 = Low
Lock Mode
F-19
0 = Panel lock: allow output off
USB/GPIB setting
Rear Panel USB Mode
F-22
2 = USB CDC, Auto Detect Speed
GPIB address
F-23
8
LAN setting
LAN
F-36
1 = Enable
DHCP
F-37
1 = Enable
Sockets active
F-57
1 = Enable
Web Server active
F-59
1 = Enable
Web password active
F-60
1 = Enable
Summary of Contents for Keithley 2260B Series
Page 14: ...2260B Series User Manual 10 Considerations 33 Grounding 36 ...
Page 43: ...OPERATION 39 Remove Test Sequence 99 Test Sequence Error Messages 100 ...
Page 52: ...2260B Series User Manual 48 Removal Reverse the procedure to remove the terminal covers ...
Page 111: ...CONFIGURATION 107 Note Power On and Calibration settings can only be set during power up ...