2260B Series User Manual
178
Protection Function
Over voltage protection
(OVP)
Setting range
V
3-33
8-88
20-275
20-880
Setting accuracy
± (2% of rated output voltage)
Over current protection
(OCP)
Setting range
A
3.6-39.6
1.35-14.85 0.45-4.95
0.144-
1.584
Setting accuracy
± (2% of rated output current)
Over temperature protection
(OTP)
Operation
Turn the output off.
Low AC input protection
(AC-FAIL)
Operation
Turn the output off.
Power limit (POWER LIMIT)
Operation
Over power limit.
Value (fixed)
Approx. 105% of rated output power
Analog Programming and Monitoring
External voltage control
output voltage at 23
˚
C±5
˚
C
Accuracy and linearity: ±0.5% of rated
output voltage.
External voltage control
output current at 23
˚
C±5
˚
C
Accuracy and linearity: ±1% of rated output
current.
External resistor control
output voltage at 23
˚
C±5
˚
C
Accuracy and linearity: ±1.5% of rated
output voltage.
External resistor control
output current at 23
˚
C±5
˚
C
Accuracy and linearity: ±1.5% of rated
output current.
Output voltage monitor
at 23
˚
C±5
˚
C
Accuracy
%
±1
±1
±2
±2
Output current monitor
at 23
˚
C±5
˚
C
Accuracy
%
±1
±1
±2
±2
Shutdown control
Turns the output off with a LOW (0V to
0.5V) or short-circuit.
Output on/off control
Possible logic selections:
Turn the output on using a LOW (0V to
0.5V) or short-circuit, turn the output off
using a HIGH (4.5V to 5V) or open-circuit.
Turn the output on using a HIGH (4.5V to
5V) or open-circuit, turn the output off
using a LOW (0V to 0.5V) or short-circuit.
Summary of Contents for Keithley 2260B Series
Page 14: ...2260B Series User Manual 10 Considerations 33 Grounding 36 ...
Page 43: ...OPERATION 39 Remove Test Sequence 99 Test Sequence Error Messages 100 ...
Page 52: ...2260B Series User Manual 48 Removal Reverse the procedure to remove the terminal covers ...
Page 111: ...CONFIGURATION 107 Note Power On and Calibration settings can only be set during power up ...