OPERATION
75
Parallel / Series Operation
This section describes the basic operations required to operate the
power supply in series or parallel. Operating the 2260B power
supplies in parallel increases the total power output of the power
supply units. When used in series, the total output voltage of the
power supplies can be increased.
The number of the power supplies that can be connected in series
or parallel depends on the model and the mode:
Series Mode: 2 units maximum; 30V and 80V models only.
Parallel Mode: 3 units maximum
CAUTION
250V and 800V models do not support series
operation!
To use the power supplies in series or parallel, units must be used
in a Master-Slave configuration. In the master-slave configuration a
“master” power supply controls any other connected “slave”
power supplies.
Master-Slave Parallel overview
→ from page
Parallel connection
→ from page
Parallel operation
→ from page
Master-Slave Series overview
→ page
Series connection
→ page
Series operation
→ from page
Before operating the power supply, please see the Getting Started
chapter, page 9.
Summary of Contents for Keithley 2260B Series
Page 14: ...2260B Series User Manual 10 Considerations 33 Grounding 36 ...
Page 43: ...OPERATION 39 Remove Test Sequence 99 Test Sequence Error Messages 100 ...
Page 52: ...2260B Series User Manual 48 Removal Reverse the procedure to remove the terminal covers ...