Troubleshooting NICE3000
new
User Manual
- 222 -
Fault
Code
Name
Possible Causes
Solution
Level
Err35
Shaft auto-
tuning data
abnormal
1. The elevator is not at
the bottom floor when
shaft auto-tuning is
started.
2. No leveling signal
is received within 45s
continuous running.
3. The distance
between two floors is
too small.
4. The maximum
number of landing
floors is inconsistent
with the setting value.
5. The floor pulses
change inversely.
6. The system is not
in the inspection state
when shaft auto-tuning
is performed.
7. Shaft auto-tuning
is not performed upon
power-on.
3. If Err35 is reported during
running, check:
•
Whether the running times out:
No leveling signal is received
when the running time exceeds
F9-02
• Whether the super short floor
function is enabled when the
floor distance is less than 50 cm
•
Whether the setting of F6-00
(Top floor of the elevator) is
smaller than the actual condition
4: If Err35 is reported when the
elevator arrives at the top floor,
check:
• Whether the obtained top floor of
the elevator and bottom floor of
the elevator are consistent with
the setting of F6-00 and F6-01
when the up slow-down signal is
valid and the elevator reaches
the door zone
• Whether the obtained floor
distance is less than 50 cm
5. If Err35 is reported at power-on,
check whether the detected flag
length is 0.
(End)
4C
Err36
RUN contactor
feedback
abnormal
1. The feedback of
the RUN contactor
is effective at startup
of the elevator, but
the contactor has no
output.
2. The controller
outputs the RUN signal
but receives no RUN
feedback during the
startup.
3. When both feedback
signals of the RUN
contactor are enabled,
their states are
inconsistent.
1. Check whether the feedback
contact of the contactor acts
properly.
2. Check the signal feature (NO,
NC) of the feedback contact.
3. Check whether the output
cables UVW of the controller are
connected properly.
4. Check whether the control circuit
of the RUN contactor coil is normal.
5A
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......