Function Code
Parameter Name
Setting Range
Default
Unit
Property
F6-13
Security floor
0 to F6-00
0
-
★
It is used to set the security floor of the elevator. If the security signal is active or it is during
the night security period, the elevator runs to the security floor first every time, stops and
opens the door, and then runs to the target floor.
The elevator can be made to stop at the security floor in the following two ways:
•
Fd-07/Fd-08 is set to 5 (Security signal). If the security signal is active, the elevator
enters the security state.
•
The night security floor function is enabled (FE-32 Bit5 = 2), the elevator enters the
security state from 22:00 p.m. to 6:00 a.m.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F6-14
Start time of down
collective selective 1
00.00–23.59
00.00
HH.MM
☆
F6-15
End time of down
collective selective 1
00.00–23.59
00.00
HH.MM
☆
F6-16
Start time of down
collective selective 2
00.00–23.59
00.00
HH.MM
☆
F6-17
End time of down
collective selective 2
00.00–23.59
00.00
HH.MM
☆
These four parameters define the time periods of down collective selective 1 and down
collective selective 2, during which, the elevator responds to only downward hall calls.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F6-18
Start time of time-based
floor service 1
00.00–23.59
00.00
HH.MM
☆
F6-19
End time of time-based
floor service 1
00.00–23.59
00.00
HH.MM
☆
F6-20
Service floor 1 of time-
based floor service 1
0–65535
65535
-
☆
F6-21
Service floor 2 of time-
based floor service 1
0–65535
65535
-
☆
F6-36
Service floor 3 of time-
based floor service 1
0–65535
65535
-
☆
F6-22
Start time of time-based
floor service 2
00.00–23.59
00.00
HH.MM
☆
F6-23
End time of time-based
floor service 2
00.00–23.59
00.00
HH.MM
☆
F6-24
Service floor 1 of time-
based floor service 2
0–65535
65535
-
☆
F6-25
Service floor 2 of time-
based floor service 2
0–65535
65535
-
☆
F6-37
Service floor 3 of time-
based floor service 2
0–65535
65535
-
☆
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......