System Commissioning and Application Example NICE3000
new
User Manual
- 94 -
Bit
Function
Description
Binary Setting
Remarks
Bit14
Emergency
evacuation
exit mode
1 Exit at door close limit
-
0 Exit at door open limit
-
Bit15
Function
selection of
shorting stator
braking mode
1 Enable this function.
When this function
is enabled, the
setting of related
function codes
becomes effective.
5.2.2 Parallel Control of Two Elevators
The NICE3000
new
supports parallel control of two elevators, which is implemented by using
the CANbus communication port for information exchange and processing between the two
elevators. The NICE3000
new
also supports group control of three to eight elevators if a group
control board is used. This implements coordination between multiple elevators to respond
to hall calls and improves the elevator use efficiency.
The NICE3000
new
is compatible with the NICE3000 and NICE5000. This section describes
the use of two elevators in parallel control. For use of multiple elevators in group control,
refer to the description of the group control board or contact Monarch.
■
Communication Ports for Parallel Control
The following table lists the parameter setting of parallel control.
Table 5-8 Parameter setting of parallel control by means of communication ports
Function
Code
Parameter Name
Setting Range
Setting in Parallel Control
F6-07
Number of elevators
in group mode
1–8
2
F6-08
Elevator No.
1–8
Master elevator: 1
Slave elevator: 2
F6-09
Program control
selection 2
Bit2: Parallel
implemented at
monitoring port
Bit2 = 1 when CN5 of the
RS232 communication port is
used for parallel control
Bit3: Parallel
implemented at
CAN2
Bit3 = 1 when CN4 of the CAN2
communication port is used for
parallel control
Bit4: Parallel control
in compatibility with
NICE3000
Bit4 = 1 when the NICE3000
is involved in parallel/group
control
Note
By default, the CAN1 communication port is used for parallel control by default. Therefore, you
need not select the parallel control port.
When the CAN2 communication port is used for parallel control, you need not set the CTB address
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......