NICE3000
new
User Manual Function Code Table
- 123 -
Function
Code
Parameter Name
Setting Range
Default
Unit
Property
Group FA: Keypad setting parameters
FA-00
Keypad display
selection
0: Reversed display of
physical floor
1: Positive display of
physical floor
2: Reversed display of
hall call floor
3: Positive display of hall
call floor
3
-
☆
FA-01
Display in running
state
1–65535
65535
-
☆
FA-02
Display in stop state
1–65535
65535
-
☆
FA-03
Current encoder angle 0.0–359.9
0.0
Degree
(°)
●
FA-05
Control board software
(ZK)
0–65535
0
-
●
FA-06
Drive board software
(DSP)
0–65535
0
-
●
FA-07
Heatsink temperature
0–100
0
°C
●
FA-11
Pre-torque current
0.0–200.0
0
%
●
FA-12
Pre-torque current
0.0–200.0
0
-
●
FA-13
Curve information
0–65535
0
-
●
FA-14
Set speed
0.000–4.000
0
m/s
●
FA-15
Feedback speed
0.000–4.000
0
m/s
●
FA-16
Bus voltage
0–999.9
0
V
●
FA-17
Present position
0.00–300.0
0
m
●
FA-18
Output current
0.0–999.9
0
A
●
FA-19
Output frequency
0.00–99.99
0
Hz
●
FA-20
Torque current
0.0–999.9
0
A
●
FA-21
Output voltage
0–999.9
0
V
●
FA-22
Output torque
0–100
0
%
●
FA-23
Output power
0.00–99.99
0
kW
●
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......