NICE3000
new
User Manual Mechanical and Electrical Installation
- 39 -
Mark
Code
Terminal Name
Function Description
Terminal Arrangement
CN7
Y1/M1
to
Y6/M6
Relay output
Normally-open (NO),
maximum current and
voltage rating: 5 A, 250
VAC
Function set in F5-26 to F5-
31
CN7
Y1
M1
Y2
M2
Y3
M3
Y4
M4
Y5
M5
Y6
M6
CN4
CAN2+/-
CAN2
differential
signal
CAN2 communication
interface, used for group
control or parallel control
CN4
CAN2+ CAN2- GND
CN5
DB9
interface
RS232
communication
interface
Used as the interface for
commission software,
cell monitoring, RS232/
RS485 parallel control, and
software download for the
MCB and drive board
5
4
3
2
1
9
8
7
6
CN5
CN12
RJ45
interface
Operation
panel interface
Used to connect the LED
or LCD operator
CN12
J1
Optional grounding terminal for AI. The pins marked with
"COM" are connected to the ground.
J1
COM
J5
Used to connect the terminal resistor for the CANbus
communication control board; the pins marked with "ON"
are connected to the terminal resistor.
J5
ON
J7
Grounding terminal of the control board. If it is shorted, the
ground of the control board is connected to the ground of
the AC drive.
J7
J12
Interface for connecting the PG card
J12
J9/
J10
Factory reserved. Do not short them randomly. Otherwise,
the controller may not be used properly.
-
Table 3-3 Description of indicators on the MCB
Mark
Terminal Name
Function Description
COP
CAN1
communication
indicator
When communication between the MCB and the CTB
is normal, this indicator is on (green).
HOP
Modbus
communication
indicator
When communication between the MCB and the HCB
is normal, this indicator is on (green).
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......