NICE3000
new
User Manual Description of Function Codes
- 187 -
FA-35 Hall state
No.
Function
No.
Function
No.
Function
No.
Function
0
Reserved
4
VIP signal
8
Reserved
12 Reserved
1
Elevator lock signal
5
Reserved
9
Reserved
13 Reserved
2
Fire emergency
signal
6
Door close
button input
10
Reserved
14 Reserved
3
Current floor
forbidden
7
Reserved
11
Reserved
15 Reserved
FA-36 System state 1
FA-37 System state 2
No.
Function
No.
Function
No.
Function
No.
Function
0
Door open 1 button
8
Door open 2
button
0
Up direction
display
8
Reserved
1
Door close 1 button
9
Door close 2
button
1
Down direction
display
9
Reserved
2
Door open delay 1
10 Door open 2
2
Running state
10 Reserved
3
Direct travel ride
switch
11 Reserved
3
System full-
load
11 Reserved
4
Attendant switch
12 Reserved
4
System
overload
12 Reserved
5
Direction change
switch
13 Reserved
5
System half-
load
13 Reserved
6
Independent
running switch
14 Reserved
6
System light-
load
14 Reserved
7
Fire emergency 2
switch
15 Reserved
7
Reserved
15 Reserved
Function Code
Parameter Name
Setting Range
Default
Unit
Property
FA-46
Hall call communication state 1
0–65535
0
-
●
FA-47
Hall call communication state 2
0–65535
0
-
●
FA-48
Hall call communication state 3
0–65535
0
-
●
These parameters display the communication state between HCBs of all floors and the
MCB.
FA-46, FA-47, and FA-48 respectively indicate the communication state of floors 1 to 16,
17 to 32, and 33 to 40. As shown in Figure 7-4, LEDs 5 and 4 show the floor address; LED
3 show whether the communication for this floor address is normal ("1" is displayed) or
interrupted ("0" is displayed). The communication quality can be viewed from LEDs 1 and
2: The 16 segments show the communication state of 16 floor addresses; ON indicates that
the communication is normal, and OFF indicates that the communication is interrupted.
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......