NICE3000
new
User Manual Description of Function Codes
- 139 -
Function
Code
Parameter Name
Setting Range
Default
Unit
Property
F1-05
Rated motor rotational
speed
0–3000
Model
dependent
RPM
★
Set these parameters according to the motor nameplate.
Ensure that these motor parameters are set correctly. Incorrect setting affects the motor
auto-tuning and the vector control effect.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F1-06
Encoder initial angle
(synchronous motor)
0.0–359.9
0
Degree
(°)
★
F1-07
Encoder angle at power-
off (synchronous motor)
0.0–359.9
0
Degree
(°)
★
F1-08
Synchronous motor
wiring mode
0–15
0
-
★
These parameters are obtained by means of motor auto-tuning.
F1-06 specifies the encoder angle at zero point. After multiple times of auto-tuning, compare
the obtained values, and the value deviation of F1-06 shall be within ±5°.
F1-07 specifies the angle of the magnetic pole when the motor is powered off. The value is
recorded at power-off and is used for comparison at next power-on.
F1-08 specifies the motor wiring mode, that is, whether the output phase sequence of the
drive board is consistent with the UVW phase sequence of the motor. If the value obtained
by means of no-load auto-tuning is an even number, the phase sequence is correct. If the
value is an odd number, the sequence is incorrect; in this case, exchange any two of UWW
phases of the motor.
Note
With-load auto-tuning of the synchronous motor can be performed only when the UVW phase
sequence of the motor is consistent with the output phase sequence of the controller.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F1-09
Current filter time
(synchronous motor)
0–40
0
-
★
It is used to set the current filter time, which suppress the periodic vertical jitter. Increase the
value in ascending order of 3 to achieve the optimum effect.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F1-10
Encoder verification selection
0–65535
0
-
★
It is used to set encoder signal verification. This parameter is set by the manufacturer, and
you need not modify it generally.
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......