Description of Function Codes NICE3000
new
User Manual
- 200 -
Fr-00
Leveling
adjustment function
0: Disabled
1: Enabled
0
-
★
This parameter is used to enable the leveling adjustment function.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
Fr-01
Leveling adjustment record 1
00000–60060
30030
mm
★
Fr-02
Leveling adjustment record 2
30030
mm
★
…
…
Fr-20
Leveling adjustment record 20
30030
mm
★
These parameters are used to record the leveling adjustment values. Each parameter
records the adjustment information of two floors, and therefore, the adjustment information
of 40 floors can be recorded totally.
The method of viewing the record is shown in the following figure.
Figure 7-9 Viewing the leveling adjustment record
Floor 1
Floor 2
Unit: mm
As shown in the preceding figure, the left two LEDs and the right two LEDs respectively
show the adjustment bases of floor 1 and floor 2. If the value is larger than 30, it is upward
leveling adjustment; if the value is smaller than 30, it is downward leveling adjustment. The
default value "30" indicates that there is no leveling adjustment. The maximum adjustment
range is ± 30 mm.
The leveling adjustment method is as follows:
17. Ensure that shaft auto-tuning is completed successfully, and the elevator runs properly
at normal speed.
18. Set Fr-00 to 1 to enable the car leveling adjustment function. Then, the elevator shields
hall calls, automatically runs to the top floor, and keeps the door open after arrival. If the
elevator is at the top floor, it directly keeps the door open.
19.
Go into the car, press the top floor button, and the leveling position is changed 1 mm
upward; press the bottom floor button, and the leveling position is changed 1 mm
downward. The value is displayed in the car.
Positive value: up arrow + value, negative value: down arrow + value, adjustment range:
± 30 mm
20.
After completing adjustment for the current floor, press the top floor button and bottom
floor button in the car at the same time to save the adjustment result. The car display
restores to the normal state. If the leveling position of the current floor need not be
adjusted, press the top floor button and bottom floor button in the car at the same time
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......