Function Code Table NICE3000
new
User Manual
- 114 -
Function
Code
Parameter Name
Setting Range
Default
Unit
Property
F6-07
Number of elevators in
group mode
1–8
1
-
★
F6-08
Elevator No.
1–8
1
-
★
F6-09
Elevator program
control
Bit0: Dispersed waiting
Bit2: Parallel
implemented at
monitoring port
Bit3: Parallel
implemented at CAN2
Bit4: Parallel control
in compatibility with
NICE3000
Bit6: Clear floor number
and display direction in
advance
Bit8: Single hall call
button
Bit10: Err30 judgment at
re-leveling cancellation
Bit14: Time interval
detection of safety circuit
2 and door lock circuit 2
0
-
★
F6-10
Leveling sensor filter
time
10–50
14
ms
★
Summary of Contents for NICE3000 New