NICE3000
new
User Manual System Commissioning and Application Example
- 83 -
Table 5-2 Output state of the running and brake contactors
Control mode
Output State
No-load Auto-
tuning
(F1-11 = 2)
With-load Auto-tuning
(F1-11 = 1)
Operation
Panel
Control
(F0-01 = 0)
Distance
Control
(F0-01 = 1)
Synchronous
motor
Asynchronous
Motor
RUN contactor
Output
Output
Output
Not output
Output
Brake contactor
Not output
Output
Not output
Not output
Output
5.1.3 Trial Running at Normal Speed
After ensuring that running at inspection speed is normal, perform shaft auto-tuning, and
then you can perform trial running at normal speed (the elevator satisfies the safety running
requirements).
To perform shaft auto-tuning, the following conditions must be satisfied:
1. The signals of the encoder and leveling sensors (NC, NO) are correct and the slow-
down switches are installed properly and act correctly.
2.
When the elevator is at the bottom floor, the down slow-down 1 switch acts.
3. The elevator is in the inspection state. The control mode is distance control and CLVC
(F0-00 = 1, F0-01 = 1).
4.
The top floor number (F6-00) and bottom floor number (F6-01) are set correctly.
5. The system is not in the fault alarm state. If there is a fault at the moment, press
STOP
RES
to reset the fault.
Then set F1-11 to 3 on the operation panel or set F7 to 1 on the keypad of the MCB, and
start shaft auto-tuning.
Note
For shaft auto-tuning when there are only two floors, the elevator needs to run to below the bottom
leveling position, that is, the leveling sensor is disconnected from the leveling plate. There is no
such requirement when there are multiple floors.
5.1.4 Door Machine Commissioning
Correlation of the door machine controller and the elevator controller is that the CTB outputs
door open/close command and the door machine controller feeds back the door open/close
limit signal.
After commissioning and installation of the door machine are complete, check whether the
wiring is correct and whether the door open/close limit signals are consistent with the default
setting. To perform the door machine commissioning, do as follows:
1. In the terminal control mode of the door machine controller, manually short the door
open relay output terminal BM/B1 and the door close relay output terminal BM/B2 on
the CTB, and observe whether the door machine can open and close correspondingly.
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......