System Commissioning and Application Example NICE3000
new
User Manual
- 100 -
Table 5-12 Selection of the opposite door mode
Opposite
Door Mode
Parameter Setting
Function Description
Use Method
Old mode (same as the NICE3000)
Mode 1
FE-33
Bit15 = 1;
Fb-00 = 2
FC-04 = 0
(Simultaneous
control)
The front door and back
door acts simultaneously
upon arrival for hall calls
and car calls.
The hall call
addresses of the
front door are set
based on floor (1-
15). The hall call
addresses of the
back door are set
based on floor +16
(17-31).
Two CCBs are
connected in serial.
The car calls of
the front door are
controlled by JP1
to JP15 of CCB1,
and the car calls of
the back door are
controlled by JP1 to
JP15 of CCB2.
A maximum of 15
floors are supported.
Mode 2
FC-04 = 1 (Hall call
independent, car
call simultaneous)
The corresponding door
opens upon arrival for hall
calls from this door. The
front door and back door
act simultaneously upon
arrival for car calls.
Mode 3
FC-04 = 2 (Hall call
independent, car
call manual control)
The corresponding door
opens upon arrival for halls
call from this door. Upon
arrival for car calls, the
door to open is selected
between the front door and
back door by using the door
switchover switch.
Mode 4
FC-04 = 3 (Hall call
independent, car
call independent)
The corresponding door
opens upon arrival for halls
call and car calls from this
door.
New mode
Mode 1
Fb-00 = 2
F8-16 =
N (N >
current
top floor
FC-04 = 0
(Simultaneous
control)
The front door and back
door act simultaneously
upon arrival for hall calls
and car calls.
The hall call
addresses of the
front door are set
based on floor (1-
N). The hall call
addresses of the
back door are set
based on floor (N+1
to 40).
The front door CCB
is connected to CN7
of the CTB, and the
back door CCB is
connected to CN8 of
the CTB.
A maximum of 20
floors are supported.
Mode 2
FC-04 = 1 (Hall call
independent, car
call simultaneous)
The corresponding door
opens upon arrival for hall
calls from this door. The
front door and back door
act simultaneously upon
arrival for car calls.
Mode 3
FC-04 = 2 (Hall call
independent, car
call manual control)
The corresponding door
opens upon arrival for halls
call from this door. Upon
arrival for car calls, the
door to open is selected
between the front door and
back door by using the door
switchover switch.
Mode 4
FC-04 = 3 (Hall call
independent, car
call independent)
The corresponding door
opens upon arrival for halls
call and car calls from this
door.
Summary of Contents for NICE3000 New
Page 1: ......
Page 13: ......
Page 14: ...1 Safety Information and Precautions ...
Page 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Page 22: ...2 Product Information ...
Page 33: ...Product Information NICE3000new User Manual 32 ...
Page 34: ...3 Mechanical and Electrical Installation ...
Page 67: ...4 Use of the NICE3000new ...
Page 79: ...5 System Commissioning and Application Example ...
Page 105: ...6 Function Code Table ...
Page 136: ...Function Code Table NICE3000new User Manual 134 ...
Page 137: ...7 Description of Function Codes ...
Page 205: ...8 EMC ...
Page 214: ...EMC NICE3000new User Manual 212 ...
Page 215: ...9 Troubleshooting ...
Page 230: ......
Page 233: ......