Super Systems Inc.
Page 78 of 107
Color Touch Screen Data Logger Operations Manual
Tag
Description
Usage
SDS:NOTE
Notes for the survey
<SDS:NOTE>
SDS:TOL
Survey tolerance / uniformity required
<SDS:TOL>
SDS:OTS
Overtemp setpoint
<SDS:OTS>
SDS:SP
Survey setpoint
<SDS:SP>
SDS:TCN
Number of thermocouples
<SDS:TCN>
SDS:TCT
Thermocouple type
<SDS:TCT>
SDS:TCS
Thermocouple spool number
<SDS:TCS>
SDS:TCC
Thermocouple calibrated by
<SDS:TCC>
SDS:TCCD
Thermocouple calibration date
<SDS:TCCD>
SDS:TCCF
Thermocouple spool correction factor
<SDS:TCCF>
SDS:SDN
Next survey due date
<SDS:SDN>
SDS:SDSM
Survey box make/model
<SDS:SDSM>
SDS:SDSS
Survey box serial number
<SDS:SDSS>
SDS:SDSC
Survey box calibrated by
<SDS:SDSC>
SDS:SDSCD
Survey box calibration date
<SDS:SDSCD>
SDS:SDSCF
Survey box correction factor
<SDS:SDSCF>
SDS:SPEC
Specifications the survey meets
<SDS:SPEC>
SDS:INT
Sample interval
<SDS:INT>
SDS:T
Temperature character – F or C
<SDS:T>
SDS:SIM
Simulate load, in pounds
<SDS:SIM>
SDS:OVS
Overshoot (Deprecated)
<SDS:OVS>
SDS:MIC
Microns
<SDS:MIC>
SDS:RES
Survey result
<SDS:RES>
SDS:GRAPH600x400 Inserts a 600X400 image of the graph
<SDS:GRAPH600x400>
SDS:COM
Company name
<SDS:COM>
SDS:UDUR
User defined survey duration
<SDS:UDUR>
SDS:UTCN
User defined number of thermocouples
<SDS:UTCN>
SDS:PCT
PID cycle time
<SDS:PCT>
SDS:PDB
PID dead band
<SDS:PDB>
SDS:POL
PID output limit
<SDS:POL>
SDS:PPB
PID PB (gain)
<SDS:PPB>
SDS:PR
PID rate
<SDS:PR>