2-5
764333-675
NOTE: If compressor does not shut off within two
minutes, test does not continue to AIR TEST X:XX
screen. At end of countdown, if compressor stayed off,
display shows:
AIR TEST
PASSED TEST
Display shows:
AIR TEST
DEFLATING SEAL
Display shows:
MFG TESTS
VALUES CALIB
• Battery
This section allows factory to turn off battery for long-
term storage. This is not used in the field.
2.1.4 Tests
Select
TESTS
, then press
SAVE VALUES
touch pad.
Display shows: VALVES INPUT CONSOLE MORE
• Valves
Select
VALVES
, then press
SAVE VALUES
touch pad.
Display shows:
tk s8 s5 s3 s4
s7 s2 s1 h p1 p2
At this point, the following outputs can be checked:
tk - Paper Take-up
s8 - Air-water solenoid valve (SOL8)
s5 - Dump valve (SOL5)
s3 - Circulation pinch valve solenoid (SOL3)
s4 - Drain pinch valve solenoid (SOL4)
s7 - Inlet fill valve (SOL7)
s2 - Seal release valve (SOL2)
s1 - Compressor release solenoid (SOL1) and enable
compressor (COMP1)
h - Heater element (HTR1)
p1 - Circulation pump (P1)
p2 - High pressure pump (P2)
CAUTION: Do not energize “h”, control
screen designation for heater element
(HTR1), unless chamber is full of water;
element failure will occur.
CAUTION: Do not energize “s2”, control
screen designation for seal release valve
(SOL2), with water in the chamber; spill will
occur.
Test each output, one at a time, by using left or right
arrow touch pad (< or >). The designator blinks when
selected.
Check for proper ON and OFF operation shown on
display (CAPITAL LETTERS = energized, lowercase
= de-energized). Press
ENTER
to energize output,
press
ENTER
again to de-energize.
NOTE: While in VALVES, the STATUS touch pad can
be used to cycle through the screens to view the
analogs inputs. Pressing the PAPER FEED touch pad
forces the unit to print the status of the LS6 and float
block switch (LS3).
Press
CANCEL
when done. Display shows:
MFG TESTS
VALUES CALIB
Select
TESTS
, then press
SAVE VALUES
touch pad.
Display shows:
VALVES INPUT
CONSOLE MORE
!
!
Summary of Contents for SYSTEM 1E
Page 1: ...MAINTENANCE MANUAL SYSTEM 1E Liquid Chemical Sterilant Processing System 12 09 10 P764333 674 ...
Page 3: ......
Page 71: ...5 19 764333 675 Figure 5 2 Analog Cable Assembly Pin Out Locations ...
Page 74: ...5 22 764333 675 Figure 5 7 DC Power Supply Harness Pin Out Locations PS P1 ...
Page 96: ...7 19 764333 675 Figure 7 17 Aquafine STERIUV5 Control Panel The Control Panel A B 3 2 1 ...
Page 108: ......
Page 110: ...ii 764333 676 Example 1 How To Use IPB Page Typical ...
Page 119: ...10 764333 676 Figure 1 SYSTEM 1E Piping Schematic ...
Page 121: ...12 764333 676 Figure 2 SYSTEM 1E Complete 4 3 2 ...
Page 128: ...19 764333 676 Figure 5 Fluid and Air Components 2 of 2 51 53 48 47 50 49 52 ...
Page 133: ...24 764333 676 Figure 7 Float Block Switch Assembly 1 5 8 7 5 4 10 4 2 6 9 9 3 CK2 CK3 LS3 CK1 ...
Page 137: ...28 764333 676 Figure 9 Drain Block Assembly 3 4 5 6 7 3 1 2 8 CK8 TC3 ...
Page 143: ...34 764333 676 Figure 12 Bulkhead Connector Assembly 1 2 2 2 3 1 1 3 5 4 4 6 ...
Page 155: ...46 764333 676 Figure 18 Harness Cable Assemblies 1 of 2 1 2 3 4 5 6 P10 PT1 P5B P11 P2 P5A ...
Page 166: ......
Page 167: ......
Page 168: ......
Page 169: ......
Page 170: ......