5.9 Hold function
In setting mode, a hold function can be activated separately for each connected measuring point (setting
mode/scales/scale parameters/hold mode)
The following hold functions are available:
> Disabled:
Hold is deactivated
> Still/key:
Hold at standstill outside empty signal,
Cancel by pressing the on key
> Still/Empty:
Hold at standstill outside empty signal,
Cancel by releasing the scale
> Max/Key:
Hold at maximum reached value with standstill outside empty signal,
higher weight sets a new hold, lift with on key
> Max/Empty:
Hold at maximum reached value with standstill outside empty signal,
higher weight sets new hold, lifting by relieving the scale
> drag / key:
Hold each time the weight is increased without stability outside empty signal,
higher weight sets new hold,
Cancel by pressing the on key
> Drag/Empty: Hold every time the weight is increased without standstill outside empty signal,
higher weight sets new hold,
Cancel by releasing the scale.
The function is effective in all application programs.
To activate the selected hold function setting, the terminal must first be restarted.
When the hold function is activated, holding a weight value in the toolbar is indicated by the HLD symbol in
the toolbar.