![Soehnle Professional 3035 Manual Download Page 103](http://html.mh-extra.com/html/soehnle-professional/3035/3035_manual_1311905103.webp)
103
weight
The scale optimises the reference weight when additional parts are placed on the
scale.
The upper limit of the optimisation will be entered in percent of the weighing range.
Example: 50% of the weighing range 60 kg, optimisation takes place up to 30 kg.
Example: 0%, optimisation switched off.
Add Mode
selection:
off or on, factory setting: on
When "on", the display unit requests the missing parts with a message (Add xx
pieces) until the minimum reference weight is reached.
Optimisation delay
Enter
the value for the speed of reference weight calculation and reference weight
optimisation between 500 and 5,000 milliseconds. Factory setting 500msec. If
unstable ambient conditions lead to inaccurate reference weights, the calculation
time can be extended to obtain more accurate reference weights.
Preferred reference scale
Selection:
None, scale 1, scale 2, scale 3...
Determination of which scale should preferably be connected for the reference
weight determination. If REF10 or REFVariable is pressed, the display for reference
weight determination automatically switches to the scale defined here. After the
reference weight has been determined, the display switches back to the last
selected bulk scale.
Factory setting: none
3
Counting
+/- tolerance separated
Selection
from or on
Selection on means that + and - tolerances for the piece control can be defined and
queried separately.
Selection Off means that tolerance is only queried once and is therefore equal for +
and -
Factory setting: off
Data record out of tolerance Selection
inside or outside
Here it is specified whether a data record may be sent to the printer or EDP only
within the tolerance or also outside it. If the data record is also accepted outside
the tolerance, it is marked with a special character.
Factory setting: Outside
Summation out of tolerance
Selection
inside or outside
Here it is defined whether summations into the totalizing memory may only be
made for values within the tolerance or also for values outside the tolerance.
Factory setting: Outside
Delete total before new
reference weight
Select
from or on.
Selection On means that the totalizing memory must first be cleared before a new
reference weight can be determined. This prevents different counting parts from
being added together.
Factory setting: off
Totalizing or picking
Select
Totalize or Pick for the following settings.
Totalizing
means that the individual positions are taken from the scale after being
transferred to the totalizing memory.
Picking
means that the individual items remain on the scale after being transferred
to the totalizing memory and the next items are placed on the scale. Factory
setting: Totalisation
Auto totalizing / picking
Select
from or on.
On means that only the first position must be stored by pressing the Plus key, all
other positions are automatically stored in the totalizing memory according to
Summary of Contents for 3035
Page 1: ...www soehnle professional com Manual Terminal 3035 ...
Page 2: ...2 ...
Page 122: ...122 ...
Page 123: ...123 ...