104
weight and stability.
Factory setting: off
running time No. Reset
Selection
under which condition the consecutive number of the totalisation /
picking is to be reset
>
not active
>
Clear total memory
>
Switch off
>
Function key (activates a separate function key)
Factory setting: not active
3
Counting
Sum key function
Selection of
which functions are to be linked to the summary key
Displaying totals onlyAfter
pressing the Total function key, the total is displayed. The user can then decide
whether to clear the totalizing memory.
Press the F2 key Clear total to clear the total memory.
Then confirm the security prompt with the F1 to F3 keys with YES, and the total is
printed.
Display/Print/Clear total After
pressing the Total function key, the totals are displayed for 3 seconds
, the memory contents are printed and simultaneously cleared. Afterwards,
a new totalizing procedure
can
be started.
Factory setting: Display/Print/Clear
Relief factor
Input
in d via numeric keypad
The number of digit steps by which the scale must be unloaded during totalizing to
allow further weight storage in the totalizing memory. If the weight is not unloaded
the weight value is not stored in the totalizing memory, error message "Error 55
Place weight on scale".
Between 0 and 30 digit steps can be specified. At 0, you can totalise, provided that
the standstill was once gone.
Factory setting: 15 digit steps
Fixed values Reference
weight
Editing
fixed values reference weight
Selection of existing fixed values from the list
Scroll with the arrow keys F3 and F4.
Call the desired fixed value with F6 Edit.
Edit an existing fixed value from the list
Press F6 to edit the marked fixed value.
Parameter name is highlighted, call up with F6 Edit,
input via keyboard. Confirm the input with F6.
(Cancel without accepting the input with F5 Cancel)
Other parameters are processed in the same way.
Delete an existing fixed value
Scroll with the arrow keys F3 and F4.
Delete the marked fixed value with F2 Delete.
The resulting gap in the consecutive numbering is closed.
Save new fixed value
Press F1 New.
The memory location number is assigned by the machine. The first number in
brackets indicates the number of free memory locations, the second number
indicates the memory locations occupied by fixed values.
Parameter name is highlighted, call up with F6 Edit, input via keyboard. Confirm the
entry with F6 Confirm.
Summary of Contents for 3035