6.5.11 Fixed tare value memory
The use of the fixed tare memory is only possible with an optional Soehnle Professional Micro-SD card.
Known tare weights can be stored in a power-failure-proof memory and called up as required. You can store
999 reference weights in a fail-safe memory.
Each memory location has:
> three-digit serial number
> Name (alphanumeric max. 18 digits)
> tare value
a) Call up the list of fixed tare values to edit the fixed values:
Press key and then F1 Tara Fix.
Selection of existing fixed values from the list
Scroll with the arrow keys F3 or F4 until the desired memory location is reached, accept the desired fixed
value with F6 Edit.
Direct access via article number or memory location number. Enter the article number or memory location
number with the numeric keypad. Whether to call the item number or memory location number is specified in
the setting mode. Enter the article number as a search criterion left-justified and the memory location
number as a search criterion right-justified. Accept the desired fixed value with F6 Edit.
Edit an existing fixed value from the list
Press F6 to edit the marked fixed value.
Parameter Designation is highlighted, call up with F6 Edit, input with numeric/alpha keyboard.
Input with F6 Accept, abort without accepting the input with F5 Abort.
Parameter Tare value is highlighted, call up via F6 Edit, input via numeric/alpha keyboard.
Input with F6 Accept, cancel without accepting the input with F5 Cancel.
Delete an existing fixed value
Scroll with the arrow keys F3 and F4.
Delete the marked fixed value with F2 Delete. Press the F1, F2 or F3 key to confirm deletion with YES. Press
the F4, F5 or F6 keys with NO to cancel the operation.
The resulting gap in the consecutive numbering is closed.
Create and save a new fixed value
Press F1 New.
The memory location number is automatically assigned by the terminal.
The first number in brackets indicates the number of free memory locations, the second number indicates
the
memory locations occupied by
fixed tare values.
Parameter Name is highlighted, call up with F6 Edit, input with numeric/alpha keyboard.
Enter with F6 Accept, cancel without accepting the input with F5 Cancel.
Parameter Tare value is highlighted, call up via F6 Edit, input via numeric/alpha keyboard.
Input with F6 Accept, cancel without accepting the input with F5 Cancel.
Exit the list of fixed values
Press the F5 Back key to exit the list.