2-27
2
Ba
sic O
pe
ra
tio
n
(2) When print data is received from the computer, either of the following is
performed before printing.
g
If [HEATER PREF] is set to [SOFTWARE] in the MEDIA menu (
P.3-33 [(22)
HEATER PREF
]
The set temperature on the heater control menu is overwritten by the
–
temperature that is set by the RIP (print data, job), and heating starts.
When no temperature is set by the RIP (print data, job), heating starts with the
–
set temperature on the heater control menu.
g
If [HEATER PREF] is set to [HEAT PANEL] in the MEDIA menu (
P.3-33 [(22)
HEATER PREF
]
The temperature set by the RIP is ignored and heating starts with the
–
temperature set on the operation panel.
(3) When the current temperatures of the after heater, print heater, and preheater
reach temperatures that are 1°C lower than the set temperatures, the printer
starts printing.
g
When the current temperature is higher than the set temperature, the printer
starts printing before the temperature lowers. Temperature control is performed
continuously after printing starts to maintain the heaters to their set temperatures.
(4) The heater temperature can vary during printing by changing the set
temperature in the heater control menu. Even after printing is completed,
the set temperature changed in the heater control menu remains as "set
temperature." However, the initial temperature value of each heater stored in
MEDIA REG MENU remains unchanged.
(5) The subsequent printing returns to (2).
- The three heaters work in the state displayed on the LCD regardless of the means used to
set their temperatures.
- The following figure shows the heater temperature control system for printing. The delay
time and standby time can be changed with the heater menu in the offline mode.
(
P.3-59 [Heater menu])
- The standby set temperature is fixed at 35°C.
Set temperature
maintained
Standby temperature
maintained
Temperature
control end
(Time)
Standby time
Delay
time
Print heater set temperature
Preheater set temperature
After heater set temperature
Standby set temperature
Ambient temperature
(Temperature)