Required tools:
• Torx T10 screwdriver to fasten the 24 V terminal adapter
• Torx screwdriver T20 for DC link screws (Torx slot)
• Pliers for breaking out the cutouts
Table 6-3
Installing the DC link adapter and 24 V terminal adapter
7
1P
T10
0,5 Nm
1. Screw the DC link adapter on the right-
hand side of the component using the
original M4x20 screws.
Do NOT use the screw holes on the left-
hand side of the component.
3. Attach and screw on the
24 V terminal adapter using the associ‐
ated screw (provided in the accessories
pack).
4. Breakout the cutouts in the protective
flap.
5. Close the protective flap until you hear
it snap into place.
Component with mounted DC link adapt‐
er and 24 V terminal adapter
6.1.5.3
72 A DC link adapter (6SL3162-2BE00-0AA0)
If you are using the DC link adapter to supply several components, then you must install it on the
component to the far right.
Accessories
6.1 DC link adapter
Booksize power units
Equipment Manual, 01/2022, 6SL3097-6AC30-0BP0