6.1.5.1
Opening the protective flap and removing the DC link screws
Required tools:
• Flat bladed screwdriver (1 x 5.5) for releasing the protective flap
Table 6-2
Opening the protective flap and removing the DC link screws
1 x 5,5
T20
1. Release and open the protective flap. 2. Remove the upper left-hand screw
and the DC link bridge
3. Remove the lower left-hand screw and
the DC link bridge
To install the DC link adapter, it is essen‐
tial to leave the DC link busbars
①
and
②
in the component (hold firmly to pre‐
vent them falling out).
4. Remove the upper and lower right-
hand DC link screw.
6.1.5.2
43 A DC link adapter (6SL3162-2BD00-0AA0)
If you are using the DC link adapter to supply several components, then you must install it on the
component to the far right.
Accessories
6.1 DC link adapter
Booksize power units
78