WARNING
Fire due to overheating when the total length of the power cables is exceeded
Overheating can result when the total length of the power cables is exceeded. This can result
in severe injury or death due to fire and smoke.
• Ensure that the total length of all power cables (motor supply cables and DC link cables)
does not exceed the values specified in Chapter "Combination options of Line Modules with
line reactors and line filters".
NOTICE
Damage through use of incorrect DRIVE-CLiQ cables
Damage or malfunctions can occur on the devices or system when DRIVE-CLiQ cables are used
that are either incorrect or have not been approved for this purpose.
• Only use suitable DRIVE-CLiQ cables that have been approved by Siemens for the particular
application.
Note
Malfunctions due to polluted DRIVE-CLiQ interfaces
Malfunctions can occur in the system through the use of polluted DRIVE-CLiQ interfaces.
• Cover unused DRIVE-CLiQ interfaces with the supplied blanking covers.
Note for UL applications
Note
Overload protection for Smart Line Modules
The Smart Line Module has integrated overload protection according to UL 61800-5-1.
Ensure that overload protection is active by following the instructions below:
• The protection threshold is 115 % of the rated output current of the Smart Line Module.
• Using the appropriate configuration, ensure that when the Smart Line Module develops a
fault condition, a pulse inhibit is set for the Motor Modules connected to the DC link.
Smart Line Modules
5.3 Safety instructions for Smart Line Modules Booksize
Booksize power units
56
Equipment Manual, 01/2022, 6SL3097-6AC30-0BP0