Error messages
If an error occurs, output "BERROR" is set and the error number is output at output
"IERRORID" (for a description and help, see Chapter Error list AddOn (Page 374)). If several
errors are present, the oldest error will be displayed.
3.3.1.9
DCC_SCDIAG
Symbol
'&&B6&',$*
%22/
%',$*B21
,67$786
,17
Figure 3-14
DCC_SCDIAG
Brief description
The block controls the inputs and outputs for the SIMOCRANE CeCOMM diagnostic program.
Method of operation
This block may not operate in the T1 execution level. The task runtime must be at least 5 ms.
The block can require up to 4 ms computation time.
Connections
The inputs and outputs of the DCC block do not have to be connected. They are connected
internally with the "DCC_SCCOMMON" block.
Table 3-18
DCC_SCDIAG connections
Name
Type Data
type
Unit-global variables of "AddOn"
Meaning
BDIAG_ON
IN
BOOL
Diagnostics ON
ISTATUS
OUT INT
For diagnostic status, see below
Diagnostic status:
1 - Diagnostics is activated
2 - Waiting for controller
3 - Block deactivated
4 - Move diagnostics to slower task
5 - Move diagnostics behind the controller in the execution system
Overview of the software
3.3 Sway control function blocks
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
57