11.3
Hoist
P40 Maximum output velocity, hoist
This value corresponds to the maximum attainable velocity (V_POS).
Default: 1400 [mm/s]
min: 10 [mm/s]
max: 5000 [mm/s]
Access code: 0
Display: Always
Note
After confirmation of the parameter P40, a prompt will be made whether the P41, P51 and P50
parameters should be updated. Updating is meaningful only if the velocities and acceleration
rates dependent upon P40 have already been entered and only P40 needs to be adjusted once
again.
With this "update" process, parameters P41, P51, and P50 are altered in equal proportion to
P40.
P41 Positioning velocity, hoist
This value corresponds to the maximum velocity (V_REF) in the operating modes SAM, POS,
SNL and SND. To allow a slight overshoot, a value of 90% of the maximum output velocity
(P40) should be set.
Default: 1300 [mm/s]
min: 10 [mm/s]
max: 5000 [mm/s]
Access code: 0
Display: Always
P43 Prelimit switch velocity, hoist
If P115 = 0 and a prelimit switch responds, the output velocity will be limited to this value.
If P115 = 1, this value is used for the dynamic prelimit switches (P64, P68). The value refers to
the maximum output velocity P40.
Default: 10 [%]
min: 0 [%]
max: 100 [%]
Access code: 0
Display: Always
P44 Hoisting velocity for zero speed signal
If the target position of the hoist has been reached and the output velocity is less than P40 *
P44/100, the direction signal is reset. The brake can be closed.
Default: 3 [%]
min: 0 [%]
max: 75 [%]
Access code: 2
Display: Always
Parameters
11.3 Hoist
SC integrated STS, GSU
400
Operating Instructions, 07/2019, A5E48271265B AA